fastText is a library for learning of word embeddings and text classification created by Facebook's AI Research (FAIR) lab. The model allows one to create an unsupervised learning or supervised learning algorithm for obtaining vector representations for words. Facebook makes available pretrained models for 294 languages. Several papers describe the techniques used by fastText. The GitHub repository was archived on March 19, 2024.
Microsoft Teams
Microsoft Teams is a team collaboration platform developed by Microsoft as part of the Microsoft 365 suite. It offers features such as workspace chat, video conferencing, file storage, and integration with both Microsoft and third-party applications and services. Teams gradually replaced earlier Microsoft messaging and collaboration platforms, including Skype for Business, Skype, Flip, and Microsoft Classroom. The platform saw significant growth during the COVID-19 pandemic, alongside competitors such as Zoom, Slack, and Google Meet, as organizations shifted to remote work and virtual meetings. As of January 2023, Microsoft reported approximately 280 million monthly active users. == History == On August 29, 2007, Microsoft acquired Parlano, the developer of the persistent group chat tool MindAlign. Years later, on March 4, 2016, Microsoft considered acquiring Slack for $8 billion. However, the proposal was reportedly opposed by Bill Gates, who advocated for focusing on enhancing Skype for Business instead. Lu Qi, then executive vice president of Applications and Services, had led the initiative to pursue the Slack acquisition. Following Lu's departure later that year, Microsoft announced Microsoft Teams on November 2, 2016, at an event in New York City, positioning it as a direct competitor to Slack. Teams launched worldwide on March 14, 2017. The service was initially led by corporate vice president Brian MacDonald. In response to the launch, Slack published a full-page advertisement in The New York Times welcoming the competition and outlining its product philosophy. Although Slack was used by 28 companies in the Fortune 100, The Verge wrote that executives would question paying for the service if Teams provides a similar function in their company's existing Office 365 subscription. However, ZDNET noted that the platforms initially served different markets, as Teams did not support external users, making it less appealing to small businesses and freelancers, a limitation Microsoft later addressed. In response to Teams' announcement, Slack deepened in-product integration with Google services. In May 2017, Microsoft announced that Teams would replace Microsoft Classroom in Office 365 Education. A free version of Teams was released on July 12, 2018, offering most core features at no cost, albeit with limits on users and storage. In January 2019, Microsoft introduced updates targeting "Firstline Workers" to improve Teams’ performance across shared or limited-access devices. In September 2019, Microsoft announced the retirement of Skype for Business in favor of Teams, which took effect on July 31, 2021. In early 2020, Microsoft introduced a push-to-talk "Walkie Talkie" feature aimed at firstline workers using smartphones and tablets over Wi-Fi or cellular networks. The COVID-19 pandemic significantly boosted usage of Teams. On March 19, 2020, Microsoft reported 44 million daily active users. In April, the platform logged 4.1 billion meeting minutes in a single day. A public preview of Microsoft Teams for Linux was released in December 2019, but the Linux client was discontinued in 2022. In July 2020, Microsoft shut down its video game livestreaming platform Mixer, and announced that some of its technologies would be repurposed for use in Teams. On February 28, 2025, Microsoft announced that Skype would be fully retired on May 5, 2025, with users given options to export their data or transition to Microsoft Teams. In October 2025, together with other Microsoft 365 suite apps, Teams had its logo updated. == Usage == == Underlying software == Microsoft Teams, as part of the Microsoft 365 suite, utilizes SharePoint and Exchange Online. Each Team, Shared Channel, and Private Channel has its own Microsoft 365 Group and SharePoint Site used for file storage. Messages are stored in Cosmos DB and are journaled to Exchange Online mailboxes. Private messages, including messages in Private Channels, are journaled to the sender and recipients' mailboxes. Public Channel messages are journaled to their corresponding Team's group mailbox, whereas, messages from Shared Channels are journaled to their own mailboxes. Contacts and voicemail are stored in Exchange Online. Microsoft Teams client is a web-based desktop app, originally developed on top of the Electron framework which combines the Chromium rendering engine and the Node.js JavaScript platform. Version 2.0 client was rebuilt using the Evergreen version of Microsoft Edge WebView2 in place of Electron. == Features == === Chats === Teams allows users to communicate in two-way persistent chats with one or multiple participants. Participants can message using text, emojis, stickers and gifs, as well as sharing links and files. In August 2022, the chat feature was updated for "chat with yourself"; allowing for the organization of files, notes, comments, images, and videos within a private chat tab. === Teams === Teams allows communities, groups, or teams to contribute in a shared workspace where messages and digital content on a specific topic are shared. Team members can join through an invitation sent by a team administrator or owner or sharing of a specific URL. Teams for Education allows admins and teachers to set up groups for classes, professional learning communities (PLCs), staff members, and everyone. === Channels === Channels allow team members to communicate without the use of email or group SMS (texting). Users can reply to posts with text, images, GIFs, and image macros. Direct messages send private messages to designated users rather than the entire channel. Connectors can be used within a channel to submit information contacted through a third-party service. Connectors include Mailchimp, Facebook Pages, Twitter, Power BI and Bing News. === Group conversations === Ad-hoc groups can be created to share instant messaging, audio calls (VoIP), and video calls inside the client software. === Telephone replacement === A feature on one of the higher cost licencing tiers allows connectivity to the public switched telephone network (PSTN) telephone system. This allows users to use Teams as if it were a telephone, making and receiving calls over the PSTN, including the ability to host "conference calls" with multiple participants. === Meeting === Meetings can be scheduled with multiple participants able to share audio, video, chat and presented content with all participants. Multiple users can connect via a meeting link. Automated minutes are possible using the recording and transcript features. Teams has a plugin for Microsoft Outlook to schedule a Teams Meeting in Outlook for a specific date and time and invite others to attend. If a meeting is scheduled within a channel, users visiting the channel are able to see if a meeting is in progress. ==== Teams Live Events ==== Teams Live Events replaces Skype Meeting Broadcast for users to broadcast to 10,000 participants on Teams, Yammer, or Microsoft Stream. ==== Breakout Rooms ==== Breakout rooms split a meeting into small groups. This is often utilized for collaboration during trainings or any environment where having all participants speak at once could be disruptive or unfeasible. Breakout rooms can be set by the hosts to a certain length of time, after which all participants will automatically rejoin the main meeting room. ==== Front Row ==== Front Row adjusts the layout of the viewer's screen, placing the speaker or content in the center of the gallery with other meeting participant's video feeds reduced in size and located below the speaker. === Education === Microsoft Teams for Education allows teachers to distribute, provide feedback, and grade student assignments turned in via Teams using the Assignments tab through Office 365 for Education subscribers. Quizzes can also be assigned to students through an integration with Office Forms. === Protocols === Microsoft Teams is based on a number of Microsoft-specific protocols. Video conferences are realized over the protocol MNP24, known from the Skype consumer version. VoIP and video conference clients based on SIP and H.323 need special gateways to connect to Microsoft Teams servers. With the help of Interactive Connectivity Establishment (ICE), clients behind Network address translation routers and restrictive firewalls are also able to connect, if peer-to-peer is not possible. === Integrations === Microsoft Teams has integrations through Microsoft AppSource, its integration marketplace. In 2020, Microsoft partnered with KUDO, a cloud-based solution with language interpretation, to allow integrated language meeting controls. In June 2022, an update was released using AI to improve call audio through the elimination of background feedback loops and cancelling non-vocal audio. == Anti-trust controversy == In July 2023, the European Commission opened an anti-trust investigation into the possibility that Microsoft unfairly used its office suite market power to increase sales of Teams and hurt
Digital image correlation and tracking
Digital image correlation and tracking is an optical method that employs tracking and image registration techniques for accurate 2D and 3D measurements of changes in 2D images or 3D volumes. This method is often used to measure full-field displacement and strains, and it is widely applied in many areas of science and engineering. Compared to strain gauges and extensometers, digital image correlation methods provide finer details about deformation, due to the ability to provide both local and average data. == Overview == Digital image correlation (DIC) techniques have been increasing in popularity, especially in micro- and nano-scale mechanical testing applications due to their relative ease of implementation and use. Advances in computer technology and digital cameras have been the enabling technologies for this method and while white-light optics has been the predominant approach, DIC can be and has been extended to almost any imaging technology. The concept of using cross-correlation to measure shifts in datasets has been known for a long time, and it has been applied to digital images since at least the early 1970s. The present-day applications are almost innumerable, including image analysis, image compression, velocimetry, and strain estimation. Much early work in DIC in the field of mechanics was led by researchers at the University of South Carolina in the early 1980s and has been optimized and improved in recent years. Commonly, DIC relies on finding the maximum of the correlation array between pixel intensity array subsets on two or more corresponding images, which gives the integer translational shift between them. It is also possible to estimate shifts to a finer resolution than the resolution of the original images, which is often called "sub-pixel" registration because the measured shift is smaller than an integer pixel unit. For sub-pixel interpolation of the shift, other methods do not simply maximize the correlation coefficient. An iterative approach can also be used to maximize the interpolated correlation coefficient by using non-linear optimization techniques. The non-linear optimization approach tends to be conceptually simpler and can handle large deformations more accurately, but as with most nonlinear optimization techniques, it is slower. The two-dimensional discrete cross correlation r i j {\displaystyle r_{ij}} can be defined in several ways, one possibility being: r i j = ∑ m ∑ n [ f ( m + i , n + j ) − f ¯ ] [ g ( m , n ) − g ¯ ] ∑ m ∑ n [ f ( m , n ) − f ¯ ] 2 ∑ m ∑ n [ g ( m , n ) − g ¯ ] 2 . {\displaystyle r_{ij}={\frac {\sum _{m}\sum _{n}[f(m+i,n+j)-{\bar {f}}][g(m,n)-{\bar {g}}]}{\sqrt {\sum _{m}\sum _{n}{[f(m,n)-{\bar {f}}]^{2}}\sum _{m}\sum _{n}{[g(m,n)-{\bar {g}}]^{2}}}}}.} Here f(m, n) is the pixel intensity or the gray-scale value at a point (m, n) in the original image, g(m, n) is the gray-scale value at a point (m, n) in the translated image, f ¯ {\displaystyle {\bar {f}}} and g ¯ {\displaystyle {\bar {g}}} are mean values of the intensity matrices f and g respectively. However, in practical applications, the correlation array is usually computed using Fourier-transform methods, since the fast Fourier transform is a much faster method than directly computing the correlation. F = F { f } , G = F { g } . {\displaystyle \mathbf {F} ={\mathcal {F}}\{f\},\quad \mathbf {G} ={\mathcal {F}}\{g\}.} Then taking the complex conjugate of the second result and multiplying the Fourier transforms together elementwise, we obtain the Fourier transform of the correlogram, R {\displaystyle \ R} : R = F ∘ G ∗ , {\displaystyle R=\mathbf {F} \circ \mathbf {G} ^{},} where ∘ {\displaystyle \circ } is the Hadamard product (entry-wise product). It is also fairly common to normalize the magnitudes to unity at this point, which results in a variation called phase correlation. Then the cross-correlation is obtained by applying the inverse Fourier transform: r = F − 1 { R } . {\displaystyle \ r={\mathcal {F}}^{-1}\{R\}.} At this point, the coordinates of the maximum of r i j {\displaystyle r_{ij}} give the integer shift: ( Δ x , Δ y ) = arg max ( i , j ) { r } . {\displaystyle (\Delta x,\Delta y)=\arg \max _{(i,j)}\{r\}.} == Deformation mapping == For deformation mapping, the mapping function that relates the images can be derived from comparing a set of subwindow pairs over the whole images. (Figure 1). The coordinates or grid points (xi, yj) and (xi, yj) are related by the translations that occur between the two images. If the deformation is small and perpendicular to the optical axis of the camera, then the relation between (xi, yj) and (xi, yj) can be approximated by a 2D affine transformation such as: x ∗ = x + u + ∂ u ∂ x Δ x + ∂ u ∂ y Δ y , {\displaystyle x^{}=x+u+{\frac {\partial u}{\partial x}}\Delta x+{\frac {\partial u}{\partial y}}\Delta y,} y ∗ = y + v + ∂ v ∂ x Δ x + ∂ v ∂ y Δ y . {\displaystyle y^{}=y+v+{\frac {\partial v}{\partial x}}\Delta x+{\frac {\partial v}{\partial y}}\Delta y.} Here u and v are translations of the center of the sub-image in the X and Y directions respectively. The distances from the center of the sub-image to the point (x, y) are denoted by Δ x {\displaystyle \Delta x} and Δ y {\displaystyle \Delta y} . Thus, the correlation coefficient rij is a function of displacement components (u, v) and displacement gradients ∂ u ∂ x , ∂ u ∂ y , ∂ v ∂ x , ∂ v ∂ y . {\displaystyle {\frac {\partial u}{\partial x}},{\frac {\partial u}{\partial y}},{\frac {\partial v}{\partial x}},{\frac {\partial v}{\partial y}}.} DIC has proven to be very effective at mapping deformation in macroscopic mechanical testing, where the application of specular markers (e.g. paint, toner powder) or surface finishes from machining and polishing provide the needed contrast to correlate images well. However, these methods for applying surface contrast do not extend to the application of free-standing thin films for several reasons. First, vapor deposition at normal temperatures on semiconductor grade substrates results in mirror-finish quality films with RMS roughnesses that are typically on the order of several nanometers. No subsequent polishing or finishing steps are required, and unless electron imaging techniques are employed that can resolve microstructural features, the films do not possess enough useful surface contrast to adequately correlate images. Typically this challenge can be circumvented by applying paint that results in a random speckle pattern on the surface, although the large and turbulent forces resulting from either spraying or applying paint to the surface of a free-standing thin film are too high and would break the specimens. In addition, the sizes of individual paint particles are on the order of μms, while the film thickness is only several hundred nanometers, which would be analogous to supporting a large boulder on a thin sheet of paper. == Digital volume correlation == Digital Volume Correlation (DVC, and sometimes called Volumetric-DIC) extends the 2D-DIC algorithms into three dimensions to calculate the full-field 3D deformation from a pair of 3D images. This technique is distinct from 3D-DIC, which only calculates the 3D deformation of an exterior surface using conventional optical images. The DVC algorithm is able to track full-field displacement information in the form of voxels instead of pixels. The theory is similar to above except that another dimension is added: the z-dimension. The displacement is calculated from the correlation of 3D subsets of the reference and deformed volumetric images, which is analogous to the correlation of 2D subsets described above. DVC can be performed using volumetric image datasets. These images can be obtained using confocal microscopy, X-ray computed tomography, Magnetic Resonance Imaging or other techniques. Similar to the other DIC techniques, the images must exhibit a distinct, high-contrast 3D "speckle pattern" to ensure accurate displacement measurement. DVC was first developed in 1999 to study the deformation of trabecular bone using X-ray computed tomography images. Since then, applications of DVC have grown to include granular materials, metals, foams, composites and biological materials. To date it has been used with images acquired by MRI imaging, Computer Tomography (CT), micro-CT, confocal microscopy, and lightsheet microscopy. DVC is currently considered to be ideal in the research world for 3D quantification of local displacements, strains, and stress in biological specimens. It is preferred because of the non-invasiveness of the method over traditional experimental methods. Two of the key challenges are improving the speed and reliability of the DVC measurement. The 3D imaging techniques produce noisier images than conventional 2D optical images, which reduces the quality of the displacement measurement. Computational speed is restricted by the file sizes of 3D images, which are significantly larger than 2D images. For example, an
Tiki Wiki CMS Groupware
Tiki Wiki CMS Groupware or simply Tiki, originally known as TikiWiki, is a free and open source Wiki-based content management system and online office suite written primarily in PHP and distributed under the GNU Lesser General Public License (LGPL-2.1-only) license. In addition to enabling websites and portals on the internet and on intranets and extranets, Tiki contains a number of collaboration features allowing it to operate as a Geospatial Content Management System (GeoCMS) and Groupware web application. Tiki includes all the basic features common to most CMSs such as the ability to register and maintain individual user accounts within a flexible and rich permission / privilege system, create and manage menus, RSS-feeds, customize page layout, perform logging, and administer the system. All administration tasks are accomplished through a browser-based user interface. Tiki features an all-in-one design, as opposed to a core+extensions model followed by other CMSs. This allows for future-proof upgrades (since all features are released together), but has the drawback of an extremely large codebase (more than 1,000,000 lines). Tiki can run on any computing platform that supports both a web server capable of running PHP 5 (including Apache HTTP Server, IIS, Lighttpd, Hiawatha, Cherokee, and nginx) and a MySQL/MariaDB database to store content and settings. == Major components == Tiki has four major categories of components: content creation and management tools, content organization tools and navigation aids, communication tools, and configuration and administration tools. These components enable administrators and users to create and manage content, as well as letting them communicate to others and configure sites. In addition, Tiki allows each user to choose from various visual themes. These themes are implemented using CSS and the open source Smarty template engine. Additional themes can be created by a Tiki administrator for branding or customization as well. == Internationalization == Tiki is an international project, supporting many languages. The default interface language in Tiki is English, but any language that can be encoded and displayed using the UTF-8 encoding can be supported. Translated strings can be included via an external language file, or by translating interface strings directly, through the database. As of 29 September 2005, Tiki had been fully translated into eight languages and reportedly 90% or more translated into another five languages, as well as partial translations for nine additional languages. Tiki also supports interactive translation of actual wiki pages and was the initial wiki engine used in the Cross Lingual Wiki Engine Project. This allows Tiki-based web sites to have translated content — not just the user interface. == Implementation == Tiki is developed primarily in PHP with some JavaScript code. It uses MySQL/MariaDB as a database. It will run on any server that provides PHP 5, including Apache and Microsoft's IIS. Tiki components make extensive use of other open source projects, including Zend Framework, Smarty, jQuery, HTML Purifier, FCKeditor, Raphaël, phpCAS, and Morcego. When used with Mapserver Tiki can become a Geospatial Content Management System. == Project team == Tiki is under active development by a large international community of over 300 developers and translators, and is one of the largest open-source teams in the world. Project members have donated the resources and bandwidth required to host the tiki.org website and various subdomains. The project members refer to this dependence on their own product as "eating their own dogfood", which they have been doing since the early days of the project. Tiki community members also participate in various related events such as WikiSym and the Libre Software Meeting. == History == Tiki has been hosted on SourceForge.net since its initial release (Release 0.9, named Spica) in October 2002. It was primarily the development of Luis Argerich (Buenos Aires, Argentina), Eduardo Polidor (São Paulo, Brazil), and Garland Foster (Green Bay, WI, United States). In July 2003, Tiki was named the SourceForge.net July 2003 Project of the Month. In late 2003, a fork of Tiki was used to create Bitweaver. In 2006, Tiki was named to CMS Report's Top 30 Web Applications. In 2008, Tiki was named to EContent magazine's Top 100 In 2009, Tiki adopted a six-month release cycle and announced the selection of a Long Term Support (LTS) version and the Tiki Software Community Association was formed as the legal steward for Tiki. The Tiki Software Association is a not-for-profit entity established in Canada. Previously, the entire project was run entirely by volunteers. In 2010, Tiki received Best of Open Source Software Applications Award (BOSSIE) from InfoWorld, in the Applications category. In 2011, Tiki was named to CMS Report's Top 30 Web Applications. In 2012, Tiki was named "Best Web Tool" by WebHostingSearch.com, and "People's Choice: Best Free CMS" by CMS Critic. In 2016, Tiki was named as one of the "10 Best Open Source Collaboration Software Tools" by Small Business Computing. == Name == The name TikiWiki is written in CamelCase, a common Wiki syntax indicating a hyperlink within the Wiki. It is most likely a compound word combining two Polynesian terms, Tiki and Wiki, to create a self-rhyming name similar to wikiwiki, a common variant of wiki. A backronym has also been formed for Tiki: Tightly Integrated Knowledge Infrastructure. == Release Information and History == In general, the Tiki Software Community Association releases a new major version of Tiki Wiki every 8 months where prior, non-LTS, major versions are supported until the first minor version release of the next major version (i.e., 16.0 ⇒ 17.1). Starting with version 12.x, Tiki Wiki LTS is supported for 5 years where it enters a security/maintenance release cycle upon the release of the next LTS version. Tiki Wiki's release history is outlined below.
TimeTiger
TimeTiger is a time and project tracking app developed by Indigo Technologies Ltd. in Toronto, Ontario, Canada. Indigo was founded in 1997 and initially released TimeTiger in 1998. == Company == The company was incorporated in 1997 and began operations as a custom software developer. TimeTiger (internally called TaskMaster) was developed as a tool to help with Indigo's own project planning and estimating. After releasing TimeTiger as a commercial product in 1998, Indigo shifted its focus to time and project management solutions. TimeTiger first introduced support for web-based time logging in 2000, to appeal to workers who were not already tracking their time for billing reasons. Subsequent development emphasized project analysis tools. == Features == Web-based electronic time log "To Do" list to monitor project and non-project activities Pivot table report designer Role-based access control == Software integration == Reports can be exported to Microsoft Excel or saved as Excel-compatible HTML files. Microsoft Project files can be imported and exported. A Software Development Kit is available.
Medical imaging
Medical imaging is the technique and process of imaging the interior of a body for clinical analysis and medical intervention, as well as visual representation of the function of some organs or tissues (physiology). Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging. Measurement and recording techniques that are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others, represent other technologies that produce data susceptible to representation as a parameter graph versus time or maps that contain data about the measurement locations. In a limited comparison, these technologies can be considered forms of medical imaging in another discipline of medical instrumentation. As of 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States. Medical imaging equipment is manufactured using technology from the semiconductor industry, including CMOS integrated circuit chips, power semiconductor devices, sensors such as image sensors (particularly CMOS sensors) and biosensors, and processors such as microcontrollers, microprocessors, digital signal processors, media processors and system-on-chip devices. As of 2015, annual shipments of medical imaging chips amount to 46 million units and $1.1 billion. The term "noninvasive" is used to denote a procedure where no instrument is introduced into a patient's body, which is the case for most imaging techniques used. == History == In 1972, engineer Godfrey Hounsfield from the British company EMI invented the X-ray computed tomography device for head diagnosis, which is commonly referred to as computed tomography (CT). The CT nucleus method is based on the projecting X-rays through a section of the human head, which are then processed by computer to reconstruct the cross-sectional image, known as image reconstruction. In 1975, EMI successfully developed a CT device for the entire body, enabling the clear acquisition of tomographic images of various parts of the human body. This revolutionary diagnostic technique earned Hounsfield and physicist Allan Cormack the Nobel Prize in Physiology or Medicine in 1979. Digital image processing technology for medical applications was inducted into the Space Foundation's Space Technology Hall of Fame in 1994. By 2010, over 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 accounted for about 50% of total ionizing radiation exposure in the United States. Medical imaging equipment is manufactured using technology from the semiconductor industry, including CMOS integrated circuit chips, power semiconductor devices, sensors such as image sensors (particularly CMOS sensors) and biosensors, as well as processors like microcontrollers, microprocessors, digital signal processors, media processors and system-on-chip devices. As of 2015, annual shipments of medical imaging chips reached 46 million units, generating a market value of $1.1 billion. == Types == In the clinical context, "invisible light" medical imaging is generally equated to radiology or "clinical imaging". "Visible light" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Interpretation of medical images is generally undertaken by a physician specialising in radiology known as a radiologist; however, this may be undertaken by any healthcare professional who is trained and certified in radiological clinical evaluation. Increasingly interpretation is being undertaken by non-physicians, for example radiographers frequently train in interpretation as part of expanded practice. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer (also known as a radiologic technologist) is usually responsible for acquiring medical images of diagnostic quality; although other professionals may train in this area, notably some radiological interventions performed by radiologists are done so without a radiographer. As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g., radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications. === Radiography === Two forms of radiographic images are in use in medical imaging. Projection radiography and fluoroscopy, with the latter being useful for catheter guidance. These 2D techniques are still in wide use despite the advance of 3D tomography due to the low cost, high resolution, and depending on the application, lower radiation dosages with 2D technique. This imaging modality uses a wide beam of X-rays for image acquisition and is the first imaging technique available in modern medicine. Fluoroscopy produces real-time images of internal structures of the body in a similar fashion to radiography, but employs a constant input of X-rays, at a lower dose rate. Contrast media, such as barium, iodine, and air are used to visualize internal organs as they work. Fluoroscopy is also used in image-guided procedures when constant feedback during a procedure is required. An image receptor is required to convert the radiation into an image after it has passed through the area of interest. Early on, this was a fluorescing screen, which gave way to an Image Amplifier (IA) which was a large vacuum tube that had the receiving end coated with cesium iodide, and a mirror at the opposite end. Eventually the mirror was replaced with a TV camera. Projectional radiographs, more commonly known as X-rays, are often used to determine the type and extent of a fracture as well as for detecting pathological changes in the lungs. With the use of radio-opaque contrast media, such as barium, they can also be used to visualize the structure of the stomach and intestines – this can help diagnose ulcers or certain types of colon cancer. === Magnetic resonance imaging === A magnetic resonance imaging instrument (MRI scanner), or "nuclear magnetic resonance (NMR) imaging" scanner as it was originally known, uses powerful magnets to polarize and excite hydrogen nuclei (i.e., single protons) of water molecules in human tissue, producing a detectable signal that is spatially encoded, resulting in images of the body. The MRI machine emits a radio frequency (RF) pulse at the resonant frequency of the hydrogen atoms on water molecules. Radio frequency antennas ("RF coils") send the pulse to the area of the body to be examined. The RF pulse is absorbed by protons, causing their direction with respect to the primary magnetic field to change. When the RF pulse is turned off, the protons "relax" back to alignment with the primary magnet and emit radio waves in the process. This radio-frequency emission from the hydrogen atoms on water is what is detected and reconstructed into an image. The resonant frequency of a spinning magnetic dipole (of which protons are one example) is called the Larmor frequency and is determined by the strength of the main magnetic field and the chemical environment of the nuclei of interest. MRI uses three electromagnetic fields: a very strong (typically 1.5 to 3 teslas) static magnetic field to polarize the hydrogen nuclei, called the primary field; gradient fields that can be modified to vary in space and time (on the order of 1 kHz) for spatial encoding, often simply called gradients; and a spatially homogeneous radio-frequency (RF) field for manipulation of the hydrogen nuclei to produce measurable signals, collected through an RF antenna. Like CT, MRI traditionally creates a two-dimensional image of a thin "slice" of the body and is therefore considered a tomographic imaging technique. Modern MRI instruments are capable of producing images in the form of 3D blocks, which may be considered a generalization of the single-slice
Digital image
A digital image is an image composed of picture elements, also known as pixels, each with finite, discrete quantities of numeric representation for its intensity or gray level that is an output from its two-dimensional functions fed as input by its spatial coordinates denoted with x, y on the x-axis and y-axis, respectively. An image can be vector or raster type. By itself, the term "digital image" usually refers to raster images or bitmapped images (as opposed to vector images). == Raster == Raster images have a finite set of digital values, called picture elements or pixels. The digital image contains a fixed number of rows and columns of pixels. Pixels are the smallest individual element in an image, holding quantized values that represent the brightness of a given color at any specific point. Typically, the pixels are stored in computer memory as a raster image or raster map, a two-dimensional array of small integers. These values are often transmitted or stored in a compressed form. Raster images can be created by a variety of input devices and techniques, such as digital cameras, scanners, coordinate-measuring machines, seismographic profiling, airborne radar, and more. They can also be synthesized from arbitrary non-image data, such as mathematical functions or three-dimensional geometric models; the latter being a major sub-area of computer graphics. The field of digital image processing is the study of algorithms for their transformation. === Raster file formats === Most users come into contact with raster images through digital cameras, which use any of several image file formats. Some digital cameras give access to almost all the data captured by the camera, using a raw image format. The Universal Photographic Imaging Guidelines (UPDIG) suggests these formats be used when possible since raw files produce the best quality images. These file formats allow the photographer and the processing agent the greatest level of control and accuracy for output. Their use is inhibited by the prevalence of proprietary information (trade secrets) for some camera makers, but there have been initiatives such as OpenRAW to influence manufacturers to release these records publicly. An alternative may be Digital Negative (DNG), a proprietary Adobe product described as "the public, archival format for digital camera raw data". Although this format is not yet universally accepted, support for the product is growing, and increasingly professional archivists and conservationists, working for respectable organizations, variously suggest or recommend DNG for archival purposes. == Vector == Vector images resulted from mathematical geometry (vector). In mathematical terms, a vector consists of both a magnitude, or length, and a direction. Often, both raster and vector elements will be combined in one image; for example, in the case of a billboard with text (vector) and photographs (raster). Example of vector file types are EPS, PDF, and AI. == Image viewing == Image viewer software displayed on images. Web browsers can display standard internet images formats including JPEG, GIF and PNG. Some can show SVG format which is a standard W3C format. In the past, when the Internet was still slow, it was common to provide "preview" images that would load and appear on the website before being replaced by the main image (to give a preliminary impression). Now Internet is fast enough and this preview image is seldom used. Some scientific images can be very large (for instance, the 46 gigapixel size image of the Milky Way, about 194 GB in size). Such images are difficult to download and are usually browsed online through more complex web interfaces. Some viewers offer a slideshow utility to display a sequence of images. == History == Early digital fax machines such as the Bartlane cable picture transmission system preceded digital cameras and computers by decades. The first picture to be scanned, stored, and recreated in digital pixels was displayed on the Standards Eastern Automatic Computer (SEAC) at NIST. The advancement of digital imagery continued in the early 1960s, alongside development of the space program and in medical research. Projects at the Jet Propulsion Laboratory, MIT, Bell Labs and the University of Maryland, among others, used digital images to advance satellite imagery, wirephoto standards conversion, medical imaging, videophone technology, character recognition, and photo enhancement. Rapid advances in digital imaging began with the introduction of MOS integrated circuits in the 1960s and microprocessors in the early 1970s, alongside progress in related computer memory storage, display technologies, and data compression algorithms. The invention of computerized axial tomography (CAT scanning), using x-rays to produce a digital image of a "slice" through a three-dimensional object, was of great importance to medical diagnostics. As well as origination of digital images, digitization of analog images allowed the enhancement and restoration of archaeological artifacts and began to be used in fields as diverse as nuclear medicine, astronomy, law enforcement, defence and industry. Advances in microprocessor technology paved the way for the development and marketing of charge-coupled devices (CCDs) for use in a wide range of image capture devices and gradually displaced the use of analog film and tape in photography and videography towards the end of the 20th century. The computing power necessary to process digital image capture also allowed computer-generated digital images to achieve a level of refinement close to photorealism. === Digital image sensors === The first semiconductor image sensor was the CCD, developed by Willard S. Boyle and George E. Smith at Bell Labs in 1969. While researching MOS technology, they realized that an electric charge was the analogy of the magnetic bubble and that it could be stored on a tiny MOS capacitor. As it was fairly straightforward to fabricate a series of MOS capacitors in a row, they connected a suitable voltage to them so that the charge could be stepped along from one to the next. The CCD is a semiconductor circuit that was later used in the first digital video cameras for television broadcasting. Early CCD sensors suffered from shutter lag. This was largely resolved with the invention of the pinned photodiode (PPD). It was invented by Nobukazu Teranishi, Hiromitsu Shiraki and Yasuo Ishihara at NEC in 1980. It was a photodetector structure with low lag, low noise, high quantum efficiency and low dark current. In 1987, the PPD began to be incorporated into most CCD devices, becoming a fixture in consumer electronic video cameras and then digital still cameras. Since then, the PPD has been used in nearly all CCD sensors and then CMOS sensors. The NMOS active-pixel sensor (APS) was invented by Olympus in Japan during the mid-1980s. This was enabled by advances in MOS semiconductor device fabrication, with MOSFET scaling reaching smaller micron and then sub-micron levels. The NMOS APS was fabricated by Tsutomu Nakamura's team at Olympus in 1985. The CMOS active-pixel sensor (CMOS sensor) was later developed by Eric Fossum's team at the NASA Jet Propulsion Laboratory in 1993. By 2007, sales of CMOS sensors had surpassed CCD sensors. === Digital image compression === An important development in digital image compression technology was the discrete cosine transform (DCT), a lossy compression technique first proposed by Nasir Ahmed in 1972. DCT compression is used in JPEG, which was introduced by the Joint Photographic Experts Group in 1992. JPEG compresses images down to much smaller file sizes, and has become the most widely used image file format on the Internet. == Mosaic == In digital imaging, a mosaic is a combination of non-overlapping images, arranged in some tessellation. Gigapixel images are an example of such digital image mosaics. Satellite imagery are often mosaicked to cover Earth regions. Interactive viewing is provided by virtual-reality photography.