Ulead MediaStudio Pro (MSP) is real-time, timeline based prosumer level video editing software by Ulead Systems. It is a suite of 5 digital video and audio applications, including: Video Capture, Video Paint, CG Infinity, Audio Editor and Video Editor. MSP is only available on the Windows platform. Since version 8.0, CG Infinity and Video Paint are separate from the MSP suite, and are being sold as a combination product called VideoGraphics Lab (VGL). On June 18, 2008, Corel formally announced that MediaStudio Pro would be discontinued. The final MediaStudio Pro version was 8.10.0039 (Pro 8 Service Pack 1) released June 2, 2006. Corel discontinued support for MediaStudio Pro in June 2009. Version 6.0 is last version to support Windows 95, although recent versions are not compatible with Windows Vista or Windows 7. == Modules == There are 5 stand-alone modules in MSP before version 8.0, they are: Video Capture – The video capturing module in MSP. Video Paint – A frame-by-frame editor which can let user to make some image or hand-drawing effects on video frames. CG Infinity – A vector-based video editing tool which allows user to create logo animation or vector graphics on video frames. Audio Editor – The audio editing tool in MSP. It can utilize DirectX audio filters and Ulead audio filters to do audio effect processing. Video Editor – The module that users do video editing with audio/video effects. It can also utilize DirectX audio filters and 3rd party video filters to do the video editing. Since version 8.0, CG Infinity and Video Paint have been separated from the MSP suite and are being sold as a combination product called VideoGraphics Lab (VGL). == Editions == Ulead MediaStudio Pro had several editions before version 7.0. They are: Full edition: this edition includes all 5 modules. Director's Cut edition: this edition has 3 modules including Video Capture, Video Editor and Audio Editor. SE edition: SE means Simple Edition or Special Edition and is an OEM bundle version. It also includes the 3 modules as Director's Cut, however, is feature limited. Sometimes it will be given freely in video magazines. After version 7.0 only Full edition is available in the MSP suite. On June 18, 2008, Corel formally announced that MediaStudio Pro would be discontinued. == Release history ==
Sample (graphics)
In computer graphics, a sample is an intersection of a channel and a pixel. The diagram below depicts a 24-bit pixel, consisting of 3 samples for Red, Green, and Blue. In this particular diagram, the Red sample occupies 9 bits, the Green sample occupies 7 bits and the Blue sample occupies 8 bits, totaling 24 bits per pixel. Note that the samples do not have to be equal size and not all samples are mandatory in a pixel. Also, a pixel can consist of more than 3 samples (e.g. 4 samples of the RGBA color space). A sample is related to a subpixel on a physical display.
Service Assurance Agent
IP SLA (Internet Protocol Service Level Agreement) is an active computer network measurement technology that was initially developed by Cisco Systems. IP SLA was previously known as Service Assurance Agent (SAA) or Response Time Reporter (RTR). IP SLA is used to track network performance like latency, ping response, and jitter, it also helps to provide service quality. == Functions == Routers and switches enabled with IP SLA perform periodic network tests or measurements such as Hypertext Transfer Protocol (HTTP) GET File Transfer Protocol (FTP) downloads Domain Name System (DNS) lookups User Datagram Protocol (UDP) echo, for VoIP jitter and mean opinion score (MOS) Data-Link Switching (DLSw) (Systems Network Architecture (SNA) tunneling protocol) Dynamic Host Configuration Protocol (DHCP) lease requests Transmission Control Protocol (TCP) connect Internet Control Message Protocol (ICMP) echo (remote ping) The exact number and types of available measurements depends on the IOS version. IP SLA is very widely used in service provider networks to generate time-based performance data. It is also used together with Simple Network Management Protocol (SNMP) and NetFlow, which generate volume-based data. == Usage considerations == For IP SLA tests, devices with IP SLA support are required. IP SLA is supported on Cisco routers and switches since IOS version 12.1. Other vendors like Juniper Networks or Enterasys Networks support IP SLA on some of their devices. IP SLA tests and data collection can be configured either via a console (command-line interface) or via SNMP. When using SNMP, both read and write community strings are needed. The IP SLA voice quality feature was added starting with IOS version 12.3(4)T. All versions after this, including 12.4 mainline, contain the MOS and ICPIF voice quality calculation for the UDP jitter measurement.
Ciphertext expansion
In cryptography, the term ciphertext expansion refers to the length increase of a message when it is encrypted. Many modern cryptosystems cause some degree of expansion during the encryption process, for instance when the resulting ciphertext must include a message-unique Initialization Vector (IV). Probabilistic encryption schemes cause ciphertext expansion, as the set of possible ciphertexts is necessarily greater than the set of input plaintexts. Certain schemes, such as Cocks Identity Based Encryption, or the Goldwasser-Micali cryptosystem result in ciphertexts hundreds or thousands of times longer than the plaintext. Ciphertext expansion may be offset or increased by other processes which compress or expand the message, e.g., data compression or error correction coding. == Reasons why Ciphertext expansion can occur == === Probabilistic Encryption === Probabilistic encryption schemes, such as the Goldwasser-Micali cryptosystem, necessarily produce ciphertexts that are longer than the original plaintexts. This is because the set of possible ciphertexts must be larger than the set of plaintexts to achieve semantic security. === Initialization Vectors (IVs) === Many block cipher modes of operation, like Cipher Block Chaining (CBC), require the use of an Initialization Vector (IV) that is unique for each message. The IV is typically appended to the ciphertext, resulting in expansion. === Redundancy and Error Correction === Some cryptographic schemes intentionally introduce redundancy or error correction codes into the ciphertext to protect against tampering or transmission errors. This added data increases the ciphertext size. === Specific Cryptosystems === Certain cryptographic schemes, such as Cocks Identity-Based Encryption, can produce ciphertexts that are hundreds or thousands of times longer than the original plaintext. This extreme expansion is a design choice to achieve the desired security properties. Ciphertext expansion can be offset or increased by other processes that compress or expand the message, such as data compression or error correction coding. The overall impact on message size depends on the relative strengths of these competing effects.
Cryptographic Module Testing Laboratory
Cryptographic Module Testing Laboratory (CMTL) is an information technology (IT) computer security testing laboratory that is accredited to conduct cryptographic module evaluations for conformance to the FIPS 140-2 U.S. Government standard. The National Institute of Standards and Technology (NIST) National Voluntary Laboratory Accreditation Program (NVLAP) accredits CMTLs to meet Cryptographic Module Validation Program (CMVP) standards and procedures. This has been replaced by FIPS 140-2 and the Cryptographic Module Validation Program (CMVP). == CMTL requirements == These laboratories must meet the following requirements: NIST Handbook 150, NVLAP Procedures and General Requirements NIST Handbook 150-17 Information Technology Security Testing - Cryptographic Module Testing NVLAP Specific Operations Checklist for Cryptographic Module Testing == FIPS 140-2 in relation to the Common Criteria == A CMTL can also be a Common Criteria (CC) Testing Laboratory (CCTL). The CC and FIPS 140-2 are different in the abstractness and focus of evaluation. FIPS 140-2 testing is against a defined cryptographic module and provides a suite of conformance tests to four FIPS 140 security levels. FIPS 140-2 describes the requirements for cryptographic modules and includes such areas as physical security, key management, self tests, roles and services, etc. The standard was initially developed in 1994 - prior to the development of the CC. The CC is an evaluation against a Protection Profile (PP), or security target (ST). Typically, a PP covers a broad range of products. A CC evaluation does not supersede or replace a validation to either FIPS 140-1, FIPS140-2 or FIPS 140-3. The four security levels in FIPS 140-1 and FIPS 140-2 do not map directly to specific CC EALs or to CC functional requirements. A CC certificate cannot be a substitute for a FIPS 140-1 or FIPS 140-2 certificate. If the operational environment is a modifiable operational environment, the operating system requirements of the Common Criteria are applicable at FIPS Security Levels 2 and above. FIPS 140-1 required evaluated operating systems that referenced the Trusted Computer System Evaluation Criteria (TCSEC) classes C2, B1 and B2. However, TCSEC is no longer in use and has been replaced by the Common Criteria. Consequently, FIPS 140-2 now references the Common Criteria. FIPS 140-2 or FIPS 140-3 validation efforts can be in some parts reused in Common Criteria evaluations, specifically in areas related to entropy source and cryptographic algorithms.
Feed forward (control)
A feed forward (sometimes written feedforward) is an element or pathway within a control system that passes a controlling signal from a source in its external environment to a load elsewhere in its external environment. This is often a command signal from an external operator. In control engineering, a feedforward control system is a control system that uses sensors to detect disturbances affecting the system and then applies an additional input to minimize the effect of the disturbance. This requires a mathematical model of the system so that the effect of disturbances can be properly predicted. A control system which has only feed-forward behavior responds to its control signal in a pre-defined way without responding to the way the system reacts; it is in contrast with a system that also has feedback, which adjusts the input to take account of how it affects the system, and how the system itself may vary unpredictably. In a feed-forward system, the control variable adjustment is not error-based. Instead it is based on knowledge about the process in the form of a mathematical model of the process and knowledge about, or measurements of, the process disturbances. Some prerequisites are needed for control scheme to be reliable by pure feed-forward without feedback: the external command or controlling signal must be available, and the effect of the output of the system on the load should be known (that usually means that the load must be predictably unchanging with time). Sometimes pure feed-forward control without feedback is called 'ballistic', because once a control signal has been sent, it cannot be further adjusted; any corrective adjustment must be by way of a new control signal. In contrast, 'cruise control' adjusts the output in response to the load that it encounters, by a feedback mechanism. These systems could relate to control theory, physiology, or computing. == Overview == With feed-forward or feedforward control, the disturbances are measured and accounted for before they have time to affect the system. In the house example, a feed-forward system may measure the fact that the door is opened and automatically turn on the heater before the house can get too cold. The difficulty with feed-forward control is that the effects of the disturbances on the system must be accurately predicted, and there must not be any unmeasured disturbances. For instance, if a window was opened that was not being measured, the feed-forward-controlled thermostat might let the house cool down. The term has specific meaning within the field of CPU-based automatic control. The discipline of feedforward control as it relates to modern, CPU based automatic controls is widely discussed, but is seldom practiced due to the difficulty and expense of developing or providing for the mathematical model required to facilitate this type of control. Open-loop control and feedback control, often based on canned PID control algorithms, are much more widely used. There are three types of control systems: open-loop, feed-forward, and feedback. An example of a pure open-loop control system is manual non-power-assisted steering of a motor car; the steering system does not have access to an auxiliary power source and does not respond to varying resistance to turning of the direction wheels; the driver must make that response without help from the steering system. In comparison, power steering has access to a controlled auxiliary power source, which depends on the engine speed. When the steering wheel is turned, a valve is opened which allows fluid under pressure to turn the wheels. A sensor monitors that pressure so that the valve only opens enough to cause the correct pressure to reach the wheel turning mechanism. This is feed-forward control where the output of the system, the change in direction of travel of the vehicle, plays no part in the system. See Model predictive control. If the driver is included in the system, then they do provide a feedback path by observing the direction of travel and compensating for errors by turning the steering wheel. In that case you have a feedback system, and the block labeled System in Figure(c) is a feed-forward system. In other words, systems of different types can be nested, and the overall system regarded as a black-box. Feedforward control is distinctly different from open-loop control and teleoperator systems. Feedforward control requires a mathematical model of the plant (process and/or machine being controlled) and the plant's relationship to any inputs or feedback the system might receive. Neither open-loop control nor teleoperator systems require the sophistication of a mathematical model of the physical system or plant being controlled. Control based on operator input without integral processing and interpretation through a mathematical model of the system is a teleoperator system and is not considered feedforward control. == History == Historically, the use of the term feedforward is found in works by Harold S. Black in US patent 1686792 (invented 17 March 1923) and D. M. MacKay as early as 1956. While MacKay's work is in the field of biological control theory, he speaks only of feedforward systems. MacKay does not mention feedforward control or allude to the discipline of feedforward controls. MacKay and other early writers who use the term feedforward are generally writing about theories of how human or animal brains work. Black also has US patent 2102671 invented 2 August 1927 on the technique of feedback applied to electronic systems. The discipline of feedforward controls was largely developed by professors and graduate students at Georgia Tech, MIT, Stanford and Carnegie Mellon. Feedforward is not typically hyphenated in scholarly publications. Meckl and Seering of MIT and Book and Dickerson of Georgia Tech began the development of the concepts of Feedforward Control in the mid-1970s. The discipline of Feedforward Controls was well defined in many scholarly papers, articles and books by the late 1980s. == Benefits == The benefits of feedforward control are significant and can often justify the extra cost, time and effort required to implement the technology. Control accuracy can often be improved by as much as an order of magnitude if the mathematical model is of sufficient quality and implementation of the feedforward control law is well thought out. Energy consumption by the feedforward control system and its driver is typically substantially lower than with other controls. Stability is enhanced such that the controlled device can be built of lower cost, lighter weight, springier materials while still being highly accurate and able to operate at high speeds. Other benefits of feedforward control include reduced wear and tear on equipment, lower maintenance costs, higher reliability and a substantial reduction in hysteresis. Feedforward control is often combined with feedback control to optimize performance. == Model == The mathematical model of the plant (machine, process or organism) used by the feedforward control system may be created and input by a control engineer or it may be learned by the control system. Control systems capable of learning and/or adapting their mathematical model have become more practical as microprocessor speeds have increased. The discipline of modern feedforward control was itself made possible by the invention of microprocessors. Feedforward control requires integration of the mathematical model into the control algorithm such that it is used to determine the control actions based on what is known about the state of the system being controlled. In the case of control for a lightweight, flexible robotic arm, this could be as simple as compensating between when the robot arm is carrying a payload and when it is not. The target joint angles are adjusted to place the payload in the desired position based on knowing the deflections in the arm from the mathematical model's interpretation of the disturbance caused by the payload. Systems that plan actions and then pass the plan to a different system for execution do not satisfy the above definition of feedforward control. Unless the system includes a means to detect a disturbance or receive an input and process that input through the mathematical model to determine the required modification to the control action, it is not true feedforward control. === Open system === In control theory, an open system is a feed forward system that does not have any feedback loop to control its output. In contrast, a closed system uses on a feedback loop to control the operation of the system. In an open system, the output of the system is not fed back into the input to the system for control or operation. == Applications == === Physiological feed-forward system === In physiology, feed-forward control is exemplified by the normal anticipatory regulation of heartbeat in advance of actual physical exertion by the central autonomic network. Feed-forward
Bus encryption
Bus encryption is the use of encrypted program instructions on a data bus in a computer that includes a secure cryptoprocessor for executing the encrypted instructions. Bus encryption is used primarily in electronic systems that require high security, such as automated teller machines, TV set-top boxes, and secure data communication devices such as two-way digital radios. Bus encryption can also mean encrypted data transmission on a data bus from one processor to another processor. For example, from the CPU to a GPU which does not require input of encrypted instructions. Such bus encryption is used by Windows Vista and newer Microsoft operating systems to protect certificates, BIOS, passwords, and program authenticity. PVP-UAB (Protected Video Path) provides bus encryption of premium video content in PCs as it passes over the PCIe bus to graphics cards to enforce digital rights management. The need for bus encryption arises when multiple people have access to the internal circuitry of an electronic system, either because they service and repair such systems, stock spare components for the systems, own the system, steal the system, or find a lost or abandoned system. Bus encryption is necessary not only to prevent tampering of encrypted instructions that may be easily discovered on a data bus or during data transmission, but also to prevent discovery of decrypted instructions that may reveal security weaknesses that an intruder can exploit. In TV set-top boxes, it is necessary to download program instructions periodically to customer's units to provide new features and to fix bugs. These new instructions are encrypted before transmission, but must also remain secure on data buses and during execution to prevent the manufacture of unauthorized cable TV boxes. This can be accomplished by secure crypto-processors that read encrypted instructions on the data bus from external data memory, decrypt the instructions in the cryptoprocessor, and execute the instructions in the same cryptoprocessor.