Grammar systems theory

Grammar systems theory

Grammar systems theory is a field of theoretical computer science that studies systems of finite collections of formal grammars generating a formal language. Each grammar works on a string, a so-called sequential form that represents an environment. Grammar systems can thus be used as a formalization of decentralized or distributed systems of agents in artificial intelligence. Let A {\displaystyle \mathbb {A} } be a simple reactive agent moving on the table and trying not to fall down from the table with two reactions, t for turning and ƒ for moving forward. The set of possible behaviors of A {\displaystyle \mathbb {A} } can then be described as formal language L A = { ( f m t n f r ) + : 1 ≤ m ≤ k ; 1 ≤ n ≤ ℓ ; 1 ≤ r ≤ k } , {\displaystyle \mathbb {L_{A}} =\{(f^{m}t^{n}f^{r})^{+}:1\leq m\leq k;1\leq n\leq \ell ;1\leq r\leq k\},} where ƒ can be done maximally k times and t can be done maximally ℓ times considering the dimensions of the table. Let G A {\displaystyle \mathbb {G_{A}} } be a formal grammar which generates language L A {\displaystyle \mathbb {L_{A}} } . The behavior of A {\displaystyle \mathbb {A} } is then described by this grammar. Suppose the A {\displaystyle \mathbb {A} } has a subsumption architecture; each component of this architecture can be then represented as a formal grammar, too, and the final behavior of the agent is then described by this system of grammars. The schema on the right describes such a system of grammars which shares a common string representing an environment. The shared sequential form is sequentially rewritten by each grammar, which can represent either a component or generally an agent. If grammars communicate together and work on a shared sequential form, it is called a Cooperating Distributed (DC) grammar system. Shared sequential form is a similar concept to the blackboard approach in AI, which is inspired by an idea of experts solving some problem together while they share their proposals and ideas on a shared blackboard. Each grammar in a grammar system can also work on its own string and communicate with other grammars in a system by sending their sequential forms on request. Such a grammar system is then called a Parallel Communicating (PC) grammar system. PC and DC are inspired by distributed AI. If there is no communication between grammars, the system is close to the decentralized approaches in AI. These kinds of grammar systems are sometimes called colonies or Eco-Grammar systems, depending (besides others) on whether the environment is changing on its own (Eco-Grammar system) or not (colonies).

Spleak

Spleak was an IM platform where users could publish and rate content. It existed in the form of six bots covering as many subject areas: CelebSpleak, SportSpleak, VoteSpleak, TVSpleak, GameSpleak, and StyleSpleak. == Overview == Users can add a "multi-Spleak" (which contains all of the different Spleak bots in one) or add the separate bots to their IM buddy lists on MSN and AIM. Users are also allowed access to Spleak online by using a CelebSpleak, SportSpleak, or VoteSpleak widget, or through the CelebSpleak and SportSpleak applications with Facebook. Spleak was an alternate reality game and is moving to its own company, Spleak Media Network. "Celebrate Spleak" was introduced throughout 2007, launched in 2008, and was forced to retire in 2009. == Key people == Spleak was co-founded by Morten Lund and Nicolaj Reffstrup. The company's chief executive officer is Morrie Eisenburg; Josh Scott is Vice President in Product and Tyler Wells is Vice President in Engineering.

Viber

Rakuten Viber, commonly known as Viber, is a cross-platform voice over IP (VoIP) and instant messaging (IM) software application owned by the Japanese technology company Rakuten Group. The service is available as freeware for Android, iOS, Microsoft Windows, macOS and Linux. Users are registered and identified through a mobile phone number, although the service can also be accessed on desktop platforms without mobile connectivity. In addition to instant messaging, the platform allows users to exchange media such as images, videos and files, and provides a paid international calling service called Viber Out. The software was launched in 2010 by the company Viber Media, founded by Talmon Marco and Igor Magazinnik. Rakuten acquired Viber Media in 2014 and later renamed the company Rakuten Viber. The company is headquartered in Cyprus and maintains offices in London, Manila, Paris, San Francisco, Singapore, Tokyo and Beijing. == History == === Founding (2010) === Viber Media was founded in Tel Aviv, Israel, in 2010 by Talmon Marco and Igor Magazinnik. Marco and Magazinnik are also co-founders of the peer-to-peer media and file-sharing client iMesh. The company was run from Israel and was registered in Cyprus. Sani Maroli and Ofer Smocha soon joined the company as well. Marco said Viber allows instant calling and synchronization with contacts because the ID is the user's cell number. In its early days, Viber relied on a patchwork of outsourcing partners from different countries, commissioning specific solutions from external vendors — including teams based in Cyprus and Belarus. According to the company's statements, development of Viber's core functionality historically originated from its Tel Aviv office — a testament to its roots — even though the legal entity was registered elsewhere. === Early monetisation (2011) === In its first two years of availability, Viber did not generate revenues. It began doing so in 2013, via user payments for Viber Out voice calling and the Viber graphical messaging "sticker market". The company was originally funded by individual investors, described by Marco as "friends and family". They invested $20 million in the company, which had 120 employees as of May 2013. On 24 July 2013, Viber's support system was defaced by the Syrian Electronic Army. According to Viber, no sensitive user information was accessed. By the time Rakuten came forward with its acquisition deal in 2014, Viber had already stopped working with external vendors, choosing instead to consolidate development under its own offices. === Rakuten acquires Viber (2014) === On 13 February 2014, Rakuten announced they had acquired Viber Media for $900 million, and since then Viber has been owned by Rakuten, Inc., an e-commerce conglomerate headquartered in Tokyo. The sale of Viber earned the Shabtai family (Benny, his brother Gilad, and Gilad's son Ofer) some $500 million from their 55.2% stake in the company. At that sale price, the founders each realized over 30 times return on their investments. Later that year, the company established a UK presence with the incorporation of Viber UK Limited in London. Djamel Agaoua became Viber Media CEO in February 2017, replacing co-founder Marco who left in 2015. In July 2017 the corporate name of Viber Media was changed to Rakuten Viber and a new wordmark logo was introduced. Its legal name remains Viber Media, S.à r.l. based in Luxembourg. === Post-acquisition === In August 2015 Viber opened a regional office for Central and Eastern Europe in Sofia to support growth in the region. In 2017, Rakuten Viber and the World Wildlife Fund engaged in a commercial transaction aimed at raising awareness and protecting wildlife. After first using Viber to spread its message in June 2020, the International Federation of the Red Cross launched an official chatbot and community on the messaging app to combat the spread of false information, which they termed an infodemic, about COVID-19. The chatbot is still active as of June 2022, with over 1.4 million subscribers. In 2020, Rakuten Viber and the World Health Organization (the WHO) engaged in a commercial transaction for a chatbot to inform users of issues such as women's health. and an anti-smoking campaign. In the wake of the July–August 2020 Belarusian election protests, to avoid sanctions and harassment from monopolies the company closed its office in Minsk. In 2022, Ofir Eyal became Viber CEO, replacing Djamel Agaoua. Eyal is a Viber veteran; he worked as Vice President of Product in 2014 before his promotion to Chief Operating Officer in 2019. Shortly after the appointment of a new CEO, Viber continued its international expansion. In March 2022, Rakuten announced the opening of a development center in Tbilisi, Georgia, intended to support work on mobile applications and technology projects in the region. In July 2022, Rakuten Viber partnered with Rapyd to launch instant cross-border P2P payments. The company launched payments on the Viber app first in Greece and Germany, and then in other countries. In August, Mineski teamed up with Viber to develop a social minigame platform that can play off Viber's application. In May 2022, Rakuten Viber launched the premium chat service Viber Plus that offers exclusive features, including sticker market privileges, ad-free use, priority Viber support, exclusive badge, unique Viber icon, large file sharing, and more. In 2022, Viber joined the European Union’s Code of Conduct on countering illegal hate speech online. As part of this framework, the company undertook to review reported content and remove material identified as hate speech in accordance with the Code and its platform rules. In January 2024 Rakuten (the company behind Viber) established an office in Kyiv to bring together engineering and marketing departments. Alongside launching its Kyiv office the company joined Diia.City as a resident. Subsequently in October 2024 Rakuten Viber inaugurated an office in Manila to broaden its operations, in the Philippines. The company’s legal entity remains Viber Media S.à r.l., registered in Luxembourg. Viber’s engineering work has been carried out across multiple countries and through external partners, including outsourcing and near-shore vendors. As a result, its development operations are distributed internationally rather than concentrated in a single location. In December 2024, Viber was blocked in Russia. Roskomnadzor announced the nationwide blocking of the messaging app due to non-compliance with local legal requirements. == Security audit == On 4 November 2014, Viber scored 1 out of 7 points on the Electronic Frontier Foundation's "Secure Messaging Scorecard". Viber received a point for encryption during transit but lost points because communications were not encrypted with keys that the provider did not have access to (i.e. the communications were not end-to-end encrypted), users could not verify contacts' identities, past messages were not secure if the encryption keys were stolen (i.e. the service did not provide forward secrecy), the code was not open to independent review (i.e. the code was not open-source), the security design was not properly documented, and there had not been a recent independent security audit. On 14 November 2014, the EFF changed Viber's score to 2 out of 7 after it had received an external security audit from Ernst & Young's Advanced Security Centre. On 19 April 2016, with the announcement of Viber version 6.0, Rakuten added end-to-end encryption to their service. The company said that the encryption protocol had only been audited internally, and promised to commission external audits "in the coming weeks". In May 2016, Viber published an overview of their encryption protocol, saying that it is a custom implementation that "uses the same concepts" as the Signal Protocol. In 2022, Rakuten Viber won a Security Award, by test.de, a tech firm based in Germany where there are over 3 million Viber users. In 2024, Rakuten Viber received SOC certification following an audit conducted by Ernst & Young. The certification relates to the company’s controls for data protection and information security. == Market share == As of December 2016, Viber had 800 million registered users. According to Statista, there are 260 million monthly active users as of January 2019. The Viber messenger is very popular in the Philippines, Greece, Eastern Europe, Russia, the Middle East, and some Asian markets. India was the largest market for Viber as of December 2014 with 33 million registered users, the fifth most popular instant messenger in the country. At the same time there were 30 million users in the United States, 28 million in Russia and 18 million in Brazil. Viber is particularly popular in Eastern Europe, being the most downloaded messaging app on Android in Belarus, Moldova and Ukraine as of 2016. It is also popular in Iraq, Libya and Nepal. Viber is translated in 44 languages and used in more than 190 co

IEBus

IEBus (Inter Equipment Bus) is a communication bus specification "between equipments within a vehicle or a chassis" of Renesas Electronics. It defines OSI model layer 1 and layer 2 specification. IEBus is mainly used for car audio and car navigations, which established de facto standard in Japan, though SAE J1850 is major in United States. IEBus is also used in some vending machines, which major customer is Fuji Electric. Each button on the vending machine has an IEBus ID, i.e. has a controller. Detailed specification is disclosed to licensees only, but protocol analyzers are provided from some test equipment vendors. Its modulation method is PWM (Pulse-Width Modulation) with 6.00 MHz base clock originally, but most of automotive customers use 6.291 MHz, and physical layer is a pair of differential signalling harness. Its physical layer adopts half-duplex, asynchronous, and multi-master communication with carrier-sense multiple access with collision detection (CSMA/CD) for medium access control. It allows for up to fifty units on one bus over a maximum length of 150 meters. Two differential signalling lines are used with Bus+ / Bus− naming, sometimes labeled as Data(+) / Data(−). It is sometimes described as "IE-BUS", "IE-Bus," or "IE Bus," but these are incorrect. In formal, it is "IEBus." IEBus® and Inter Equipment Bus® are registered trademark symbols of Renesas Electronics Corporation, formerly NEC Electronics Corporation, (JPO: Reg. No.2552418 and 2552419, respectively). == History == In the middle of '80s, semiconductor unit of NEC Corporation, currently Renesas Electronics, started the study for increasing demands for automotive audio systems. IEBus is introduced as a solution for the distributed control system. In the late 1980s, several similar specifications, including the Domestic Digital Bus (D2B), the Japanese Home Bus (HBS), and the European Home System (EHS) are proposed by different companies or organizations. These were once discussed as IEC 61030, but it was withdrawn in 2006. IEBus is also a similar specification (refer to "Transfer signal format" section), but not listed in these criteria. As the result, IEBus becomes a de facto standard of car audio in Japan. Regarding the Domestic Digital Bus (D2B), it is re-defined as D2B Optical by Mercedes-Benz independently. As for Japanese Home Bus System (HBS), it is defined in 1988 as Home Bus System Standard Specification, ET-2101 by JEITA and REEA (Radio Engineering & Electronics Assiation) in Japan. It is being used by several Japanese air conditioner manufacturers (for example, M-Net from Mitsubishi and the P1/P2 or F1/F2 bus from Daikin). Fujitsu provided HBPC (Home Bus Protocol Controller) chip as MB86046B. But it is unclear whether Fujitsu (currently, Cypress) still manufactures this HBPC LSI as of 2018. Mitsumi Electric provides the MM1007 and MM1192 driver ICs for HBS. The HBS specification is also discussed in the Echonet Consortium. In 2014, a utility model patent for protocol converter from HBS to RS-485 is granted in China as "CN204006496U." Regarding the replacement of IEBus, a paper by Hyundai Autonet, currently Hyundai Mobis, describes as follows. "In communication methods for digital input capable amplifiers, Inter Equipment Bus (IEBus) was used in early times, but for now, Controller Area Network (CAN) is mainly used." == Protocol overview == A master talks to a slave. Each unit has a master and a slave address register. Only one device can talk on the bus at any given time. There is a pecking order for the types of communications which will take precedence over another. Each communication from master to slave must be replied to by the slave going back to the master with acknowledge bits each of those show ACK or NAK. If the master does not receive the ACK within a predefined time allowance for a mode, it drops the communication and returns to its standby (listen) mode. Detailed specification of OSI model layer 2 is disclosed to licensees only, but protocol analyzers are provided from some test equipment vendors. In 2012, one of Chinese manufacturer's patent is granted as "CN202841169U". An open-source software emulator called "IEBus Studio" exists on a repository of SourceForge, but the last update was on 2008-02-24. Another open-source analyzer software called "IEBusAnalyzer" is available on GitHub repository. Some hobbyist made some tools also. === Physical layer (OSI model layer 1) specification overview === From μPD6708 data sheet. and μPD78098B Subseries user's manual, hardware. Communication system Half-duplex asynchronous communication Multi-master system All the units connected to the IEBus can transfer data to the other units. Broadcast communication function (communication between one unit and multiple units) Normally, communication is individually carried out from one unit to another. By using the broadcast communication function, however, communication can be executed from one unit to plural units as follows: Group broadcast communication: Broadcast communication to group units Simultaneous broadcast communication: Broadcast communication to all units Effective transmission rate The effective transmission rate can be selected from the following three communication modes: Mixture of the plural of modes in the same bus line is not allowed. Correct communication between different base clock is not possible. Access control CSMA/CD (Carrier Sense Multiple Access with Collision Detection) The priority of occupying IEBus is as follows: «1» Broadcast communication takes precedence over individual communication. «2» The lower the master address, the higher the priority. Communication scale Number of units: 50 MAX. Cable length: 150 m MAX. (when a twisted pair cable is used) Load capacity: MAX. 8000 pF; between Bus+ and Bus−, (6.000000 MHz base clock) MAX. 7100 pF; between Bus+ and Bus−, (6.291456 MHz base clock) Terminating resistor: 120 Ω Logic level Logic 1: Low level. Voltage difference between Bus+ and Bus− is under 20mV Logic 0: High Level. Voltage difference between Bus+ and Bus− is over 120mV In-phase input voltage high: Bus+ ≤ (VDD-1.0) V, Bus− ≥ 1.0 V === Transfer signal format === From μPD6708 data sheet. and μPD78098B Subseries user's manual, hardware. This frame format is much similar to that of Domestic Digital Bus (D2B). All fields are MSB first. ==== Functions of Control bits ==== === Bit format === Each IEBus bit consists of four periods. Preparation period: The first or subsequent low-level (logic "1") period Synchronization period: Next high-level (logic "0") period Data period: Period indicating value of bit; ether low-level (logic "1") or high-level (logic "0") Stop period: The last low-level (logic "1") period Synchronization is done by each bit. Time lengths of the synchronization period and data period are almost the same. The time of the entire bits' and each bit's specification, related to the time of each period allocated to it, differ depending both on the type of the transmit bit and on whether the unit is the master or a slave unit. == Automotive manufacturers using IEBus == Each manufacturer has its own name, but it is not an alias of IEBus. Those are specifications of wire harness which comprise control cables based on IEBus, OSI model layer 3 and above communication protocol, audio cables, interconnection couplers, and so on. === Pioneer === Pioneer Corporation employed IEBus for its original branded car audio in early '90s. In its earlier stage, it was used just for control bus between the head unit in dashboard and the CD changer usually placed in trunk room. Nowadays, the specification includes connection between head units, navigation systems, rear speaker systems, and so on. IP-Bus: Wire harness specification. === Toyota === Pioneer Corporation pushed Toyota Motor Corporation to adopt IEBus as the genuine parts. In 1994, Toyota decided to employ IEBus for its genuine specification, but it is slightly different from that of Pioneer. It is named as AVC-LAN. AVC-LAN: Wire harness specification, based on mode 2. === Honda/Acura === Pioneer Corporation also pushed Honda Motor. Honda also decided to adopt IEBus as its genuine parts specification just after Toyota do so. GA-NET II: Wire harness specification. Honda Music Link: Honda genuine gadget to connect Apple Inc. products. A hobbyist made touch screen controller on Acura TSX for a Car PC installed in the trunk. === Sirius XM Satellite Radio === Sirius XM Satellite Radio is a satellite broadcasting radio operator in US. Its digital media receiver equipment utilizes IEBus. == Evaluation boards == === SAKURA board === GR-SAKUKRA board and GR-SAKURA-FULL board are Renesas official promotion boards of RX63N chip, which enables IEBus mode 0 and 1, but not mode 2, i.e. not available for Toyota AVC-LAN. They are an Arduino pin compatible low-price ones, suitable for hobbyists. Their color of printed circuit board is SAKURA in Japanese, which means cherry blossom. To e

Defence Information Infrastructure

Defence Information Infrastructure (DII) is a secure military network owned by the United Kingdom's Ministry of Defence MOD. It is used by all branches of the armed forces, including the Royal Navy, British Army and Royal Air Force as well as MOD civil servants. It reaches to deployed bases and ships at sea, but not to aircraft in flight. In 2000, the MOD began to plan the systems replacement project. In March 2005, the MOD gave a contract to the Atlas Consortium, with EDS as prime contractor, for installation and management over 10 years. That has developed into a consortium made up of DXC Technology (formerly EDS), Fujitsu, Airbus Defence and Space (formerly EADS Defence & Security) and CGI (formerly Logica). Starting in May 2016, MOD users of DII begin to migrate to the New Style of IT within the defence to be known as MODNET; again supported by ATLAS. == Overview == DII supports 2,000 MOD sites with some 150,000 terminals (desktops and laptops) and 300,000 user accounts. It is designed to offer a high level of resilience, flexibility, and security in the provision of connectivity from ‘business space to battlespace’ in MOD offices in the UK, bases overseas, at sea, and on the front line. It aims to rationalise and improve IT provision for the defence sector in the 21st century; involving a major culture change for MOD users and their ways of working through a structure of shared working areas with controlled security and access. It should provide a records management system and search facility together with a range of office services. It hosts several hundred COTS (commercial off-the-shelf) and bespoke MOD applications from a range of suppliers judged to meet the required security standards. The network handles alphanumeric data, graphics, and video. The system carries information from Restricted to above-Secret levels, but users are able to see only the data and applications for which they are authorised. == Incremental approach == In order to de-risk the programme Atlas and the MOD took an incremental approach to the development and implementation of DII, with a separate contract for each increment. The extended timeline allowed the MOD flexibility in defining its requirements. Increment 1: Contract awarded March 2005. This covered 70,000 user access devices (UADs) and 200,000 user accounts in the Restricted and Secret domains in 680 fixed locations. Increment 2a: Contract awarded December 2006. This was for an additional 44,000 UADs and 58,000 user accounts in the Restricted and Secret domains, again in fixed locations. Increment 2b: Contract awarded September 2007: This extended DII(F) into the deployed environment with the provision of UADs to support land and maritime deployed operations. Increment 2c: Signed in January 2009. This extended the DII footprint into the above-Secret domain to support a number of key operations and intelligence initiatives. Increment 3a: Contract awarded January 2010. Atlas provided 42,000 UADs operating in the Restricted and Secret domains to the remaining MOD fixed sites. This supported some 60,000 personnel, notably within the RAF, at Joint Helicopter Command and other MOD locations. Increment 3a received an MOD Chief of Defence Materiel commendation. == Costs and transparency == The Ministry of Defence informed Parliament the system would cost £2.3bn, even though it knew the cost would be at least £5.8bn. By 2008 the programme was running at least 18 months late; had delivered only 29,000 of a contracted 63,000 terminals; and had delivered none of the contracted Secret capability. In January 2010 the Parliamentary Under-Secretary of State for Defence announced that the Ministry of Defence had authorised DII increment 3a at a cost of around £540 million to provide 42,000 terminals within the RAF and at Joint Helicopter Command. He stated that the project would deliver "benefits" worth over £1.6 billion over the 10 years of the contract. That year the project was scheduled to cost at least £7bn, however, the UK government said it might attempt to reduce this sum. By 2014 the rollout of all UK terminals was complete and a refresh of the original desktops and printers to new hardware underway. The overseas rollout was coming to an end and well over half the fleet, including aircraft carrier HMS Queen Elizabeth, equipped. The final part of Secret capability deployment was scheduled to complete in summer of 2014.

Environmental impact of AI

The environmental impact of the design, training, deployment and use of artificial intelligence includes the greenhouse gas emissions from generating electricity for data centres and computing hardware, operational and upstream water use, and material impacts from hardware manufacturing, mining and electronic waste. Estimating AI's environmental effects can be difficult because results depend on how impacts are measured, including whether accounting includes only model computation or also data-centre overhead, idle capacity, hardware manufacture, and local electricity supply. As these issues have received greater attention, governments and regulators have increasingly considered data-centre reporting requirements, energy-efficiency standards, and broader transparency measures for AI-related resource use. == Carbon footprint and energy use == AI-related energy use arises at multiple stages, including model training, fine-tuning, inference, storage, networking, and supporting infrastructure such as cooling and power conversion. === Individual level === Published estimates of energy use per AI request vary widely across models, tasks and measurement methods. A benchmark study presented at the 2024 ACM Conference on Fairness, Accountability, and Transparency found substantial differences between task types, with lower energy use for some text tasks and much higher energy use for image generation in the study's test conditions. In that benchmark, simple classification tasks consumed about 0.002–0.007 Wh per prompt on average (about 9% of a smartphone charge for 1,000 prompts), while text generation and text summarisation each used about 0.05 Wh per prompt; image generation averaged 2.91 Wh per prompt, and the least efficient image model in the study used 11.49 Wh per image (roughly equivalent to half a smartphone charge). First-party measurements in production environments have also been published. A 2025 Google study on Gemini assistant serving reported median per-prompt energy, emissions, and water-use estimates under the authors' accounting framework, while noting that different system boundaries can produce substantially different results. The study reported a median text-prompt estimate of about 0.24 Wh, which is roughly as much energy as watching nine seconds of television. The study also stated that software and infrastructure improvements reduced energy use by a factor of 33 and carbon emissions by a factor of 44 for a typical prompt over one year within the authors' framework. Researchers at the University of Michigan measured the energy consumption of various Meta Llama 3.1 models released in 2024 and found that smaller language models (8 billion parameters) use about 114 joules (0.03167 Wh) per response, while larger models (405 billion parameters) require up to 6,700 joules (1.861 Wh) per response. This corresponds to the energy needed to run a microwave oven for roughly one-tenth of a second and eight seconds, respectively. Comparisons between AI systems and human labour for specific tasks have produced mixed results and remain sensitive to assumptions about output quality, workload and system boundaries. A 2024 study in Scientific Reports reported 130 to 2900 times lower estimated carbon emissions for selected AI systems than for human writers and illustrators under its assumptions. A later Scientific Reports paper reported a counterexample for programming tasks under its assumptions, finding 5 to 19 times higher estimated emissions for the evaluated AI system than for human programmers on the benchmark used in that study. === System level === ==== Energy use and efficiency ==== AI electricity intensity depends not only on model architecture but also on hardware and facility efficiency. Data-centre operators commonly report Power usage effectiveness (PUE), which measures the ratio of total facility energy to IT equipment energy; a lower PUE indicates less overhead energy for cooling and other supporting infrastructure. Operators may also publish metrics and case studies on hardware efficiency, cooling systems and power sourcing. In its 2024 environmental report, Google stated that its 2023 total greenhouse gas emissions increased 13% year over year, primarily because of increased data-centre energy consumption and supply-chain emissions, while also reporting lower PUE than industry averages for its own facilities. The International Energy Agency has also reported that data centres remain a relatively small share of global electricity use overall, but that their local effects can be much more pronounced because demand is geographically concentrated. ==== Carbon footprint ==== At system level, AI contributes to rising electricity demand in data centres and related infrastructure. The International Energy Agency estimated that data centres used about 415 TWh of electricity in 2024, or around 1.5% of global electricity consumption, and projected that data-centre electricity use could rise to about 945 TWh by 2030, with AI identified as the main driver of that growth alongside other digital services. The carbon footprint of AI systems depends strongly on electricity sources, hardware efficiency, utilisation rates, and what stages are included in the accounting. Training large models can require substantial electricity, while total lifecycle impacts also depend on deployment scale and the amount of inference performed after training. Early analyses of frontier-model development reported rapid historical growth in training compute for selected systems, although later trends have depended on changes in model design, hardware and efficiency gains. Accounting methods that include upstream or embodied impacts, such as hardware manufacture and facilities construction, can materially affect estimates of AI-related emissions. === Decisions and strategies by individual companies === Large technology companies have reported that the expansion of AI and cloud infrastructure affects their sustainability targets, electricity demand, and resource use. Google, for example, attributed part of its emissions growth in 2023 to increased data-centre energy consumption and supply-chain emissions in its 2024 environmental report. Cloud and AI companies have also announced measures intended to reduce environmental impacts, including investment in more efficient hardware, low-carbon electricity procurement, alternative cooling systems, and water stewardship programmes. The extent, comparability, and third-party verification of such disclosures vary between firms and jurisdictions. == Water usage == Data centres can use water directly for cooling and indirectly through the water used in electricity generation, depending on the local energy mix. Public reporting on data-centre water use has often been inconsistent, making comparisons between operators and regions difficult. To standardise operational reporting, The Green Grid proposed the metric water usage effectiveness (WUE), defined as annual site water use divided by IT equipment energy use. WUE does not by itself measure local water stress, source sustainability, or all upstream water impacts. Studies of AI water use also distinguish between water withdrawal and water consumption. Research on AI-specific water use has argued that the water footprint of AI systems can be difficult to observe and may vary substantially by location, cooling design, and electricity source. A 2025 Communications of the ACM article summarised methods for estimating AI water footprints and emphasised the distinction between water withdrawal and water consumption. Li and colleagues estimated that global AI water withdrawal could reach 4.2–6.6 billion cubic metres in 2027 under the scenarios examined in their article. Using GPT-3, released by OpenAI in 2020, as an example, they estimated that training the model in Microsoft's U.S. data centres could consume about 700,000 litres of onsite water and about 5.4 million litres in total when offsite electricity-related water use was included; they also estimated that 10–50 medium-length GPT-3 responses could consume about 500 mL of water, depending on when and where the model was deployed. Published prompt-level estimates have also varied by system and accounting framework: the 2025 Google study on Gemini assistant serving reported a median text-prompt estimate of about 0.26 mL under its framework. Location can materially affect the significance of data-centre water use. Research on U.S. data centres found that one-fifth of servers' direct water footprint came from moderately to highly water-stressed watersheds, while nearly half of servers were fully or partially powered by plants located in water-stressed regions. A 2025 Reuters report, citing data from Verisk Maplecroft and NatureFinance, said that an average mid-sized data centre uses about 1.4 million litres of water per day for cooling and that Phoenix would experience a 32% increase in annual water stress if currently pl

Data independence

Data independence is the type of data transparency that matters for a centralized DBMS. It refers to the immunity of user applications to changes made in the definition and organization of data. Application programs should not, ideally, be exposed to details of data representation and storage. The DBMS provides an abstract view of the data that hides such details. There are two types of data independence: physical and logical data independence. The data independence and operation independence together gives the feature of data abstraction. There are two levels of data independence. == Logical data independence == The logical structure of the data is known as the 'schema definition'. In general, if a user application operates on a subset of the attributes of a relation, it should not be affected later when new attributes are added to the same relation. Logical data independence indicates that the conceptual schema can be changed without affecting the existing schemas. == Physical data independence == The physical structure of the data is referred to as "physical data description". Physical data independence deals with hiding the details of the storage structure from user applications. The application should not be involved with these issues since, conceptually, there is no difference in the operations carried out against the data. There are three types of data independence: Logical data independence: The ability to change the logical (conceptual) schema without changing the External schema (User View) is called logical data independence. For example, the addition or removal of new entities, attributes, or relationships to the conceptual schema or having to rewrite existing application programs. Physical data independence: The ability to change the physical schema without changing the logical schema is called physical data independence. For example, a change to the internal schema, such as using different file organization or storage structures, storage devices, or indexing strategy, should be possible without having to change the conceptual or external schemas. View level data independence: always independent no effect, because there doesn't exist any other level above view level. == Data independence == Data independence can be explained as follows: Each higher level of the data architecture is immune to changes of the next lower level of the architecture. The logical scheme stays unchanged even though the storage space or type of some data is changed for reasons of optimization or reorganization. In this, external schema does not change. In this, internal schema changes may be required due to some physical schema were reorganized here. Physical data independence is present in most databases and file environment in which hardware storage of encoding, exact location of data on disk, merging of records, so on this are hidden from user. == Data independence types == The ability to modify schema definition in one level without affecting schema of that definition in the next higher level is called data independence. There are two levels of data independence, they are Physical data independence and Logical data independence. Physical data independence is the ability to modify the physical schema without causing application programs to be rewritten. Modifications at the physical level are occasionally necessary to improve performance. It means we change the physical storage/level without affecting the conceptual or external view of the data. The new changes are absorbed by mapping techniques. Logical data independence is the ability to modify the logical schema without causing application programs to be rewritten. Modifications at the logical level are necessary whenever the logical structure of the database is altered (for example, when money-market accounts are added to banking system). Logical Data independence means if we add some new columns or remove some columns from table then the user view and programs should not change. For example: consider two users A & B. Both are selecting the fields "EmployeeNumber" and "EmployeeName". If user B adds a new column (e.g. salary) to his table, it will not affect the external view for user A, though the internal schema of the database has been changed for both users A & B. Logical data independence is more difficult to achieve than physical data independence, since application programs are heavily dependent on the logical structure of the data that they access.