Colossus (supercomputer)

Colossus (supercomputer)

Colossus is a supercomputer developed by xAI. Construction began in 2024 in Memphis, Tennessee; the system became operational in July 2024. It is currently the world's largest AI supercomputer. Colossus's primary purpose is to train the company's chatbot, Grok. In addition, Colossus provides computing support to the social-media platform X and to other projects of Elon Musk, such as SpaceX. In 2025, it expanded to neighboring Southaven, Mississippi across the Tennessee–Mississippi border. As of May 6, 2026, Anthropic has agreed to rent all compute capacity at the Colossus 1 data center. == Background == Colossus was launched in September 2024 at a former Electrolux site in South Memphis to train the AI language model Grok. Within 19 days of the project's conception, xAI was ready to begin construction. The site was chosen because the abandoned Electrolux building could be repurposed to expedite construction and its proximity to a nearby wastewater treatment facility provided a water source. As of February 2025, xAI plans to build an $80 million facility to process additional wastewater for use at the supercomputer. === xAI === Musk incorporated xAI in March 2023 with the stated purpose of understanding the "nature of the universe". The team includes former members of OpenAI, DeepMind, Microsoft, and Tesla. Musk was one of the founding members of the company OpenAI, investing up to US$45 million in 2015. He left OpenAI in 2018, reportedly to avoid conflicts of interest with Tesla. It has also been reported that he had made a bid for leadership at OpenAI and left when his proposal was rejected. The exact reasons for his departure from the company are unclear. Both Dell Technologies and Supermicro partnered with xAI to build the supercomputer. It was originally powered by 100,000 Nvidia graphics processing units (GPUs) and was constructed in 122 days. 3 months after the first 100,000 GPUs were deployed, xAI announced that they had increased the system to 200,000 GPUs and that they intended to continue increasing the computer's processing power to 1 million GPUs. As of April 2025, xAI claimed Colossus was the largest AI training platform in the world. == Choice of location == xAI selected Memphis, in southwestern Tennessee, as the site for Colossus in part because an existing industrial facility allowed the project to proceed more quickly than constructing a new data center. Elon Musk was initially told that building a data center would take 18–24 months. The company instead searched for a vacant facility and selected the former Electrolux factory in Memphis. Electrolux opened the facility in 2012 and operated it for about eight years before closing it in 2020 after relocating operations to Springfield, Tennessee. The building covered 785,000 sq ft (72,900 m2) and had been purchased by Phoenix Investors in December 2023 for $35 million . Because the structure was already in place, work on the supercomputer could begin immediately rather than waiting for a new facility to be constructed. According to Forbes, xAI considered seven or eight other sites before selecting Memphis, and Musk finalized the decision to build in Memphis in about a week. The decision was finalized in March 2024, after which construction began. xAI publicly announced in June 2024 that Colossus would be built in Memphis. The building itself was not the only reason xAI selected Memphis. According to the Greater Memphis Chamber, the company chose the city because of its "reliable power grid, ability to create a water recycling facility, proximity to the Mississippi River and ample land". The city was also able to provide the large amounts of electricity and water needed to operate the supercomputer. At full capacity, the system was expected to require 150 megawatts of electricity and millions of gallons of water per day. The project also relied on partnerships with local and regional organizations including Memphis Light, Gas and Water (MLGW), Tennessee Valley Authority (TVA), the City of Memphis, and Shelby County. The city also provided financial incentives for the project. == Environmental impact == AI data centers consume large amounts of energy. At the site of Colossus in South Memphis, the grid connection was only 8 MW, so xAI applied to temporarily set up more than a dozen gas turbines (Voltagrid’s 2.5 MW units and Solar Turbines’ 16 MW SMT-130s) which would steadily burn methane gas from a 16-inch natural gas main. Aerial imagery in April 2025 showed 35 gas turbines had been set up at a combined 422 MW. These turbines have been estimated to generate about "72 megawatts, which is approximately 3% of the (TVA) power grid". The higher number of gas turbines and the subsequent emissions requires xAI to have a major source permit. In Memphis, xAI was able to avoid some environmental rules in the construction of Colossus, such as operating without permits for the on-site methane gas turbines because they are "portable". The Shelby County Health Department told NPR that "it only regulates gas-burning generators if they're in the same location for more than 364 days". However, in a January 2026 ruling, the EPA revised its New Source Performance Standard and announced that large methane gas turbines require permits even for temporary operations. In November 2024, the grid connection was upgraded to 150 MW, and some turbines were removed. Along with high electricity needs, the expected water demand is over five million gallons of water per day. While xAI has stated they plan to work with MLGW on a wastewater treatment facility and the installation of 50 megawatts of large battery storage facilities, there are currently no concrete plans in place aside from a one-page factsheet shared by MLGW. == Community response == The plan to build Colossus in Memphis was unknown to residents, City Council members, and environmental agencies. Many did not find out about the project until the day before, or the day of, as they watched the announcement on the local news. Keshaun Pearson, president of Memphis Community Against Pollution, stated that there is a historical lack of transparency and communication surrounding environmental issues in Memphis. Some community members in Memphis have expressed concern about the potential for additional air and water pollution caused by the supercomputer. In a letter to the Shelby County Health Department, the Southern Environmental Law Center stated the emissions from the turbines make the facility "...likely the largest industrial emitter of NOx in Memphis..." This is due to data supplied by the manufacturer showing that "...xAI emits between 1,200 and 2,000 tons of smog-forming nitrogen oxides (NOx)..." At a public Shelby County Commissioner's hearing on April 9, 2025, residents living near the site of Colossus voiced complaints about air quality, noting that they have chronic respiratory issues related to living in a polluted section of Memphis. One woman said she smells "everything but the right thing and the right thing is the clean air." Other residents voiced frustration that Brent Mayo, the senior xAI official responsible for building out xAI's infrastructure, did not attend the meeting to discuss community concerns. Keshaun Pearson also stated that "We're getting more and more days a year where it is unhealthy for us to go outside." People living near the site of Colossus have said they were not offered the opportunity for a public review of the plans, nor were they provided with information on how their community could potentially benefit. The community is also concerned about the strain on the power grid. Memphis's peak demand is around 3 GW. In November 2024, TVA approved xAI's request for access to more than 100 megawatts of power to Colossus which is supplied by MLGW. In December 2022, MLGW imposed (then rescinded) rolling blackouts during several days of extreme cold, straining the power grid. In a letter to the TVA, the SELC "urged the agency to 'prioritize Memphis families' access to reliable power over the 'secondary purpose' of serving xAI". == Current progress == In early December 2024, Ted Townsend detailed how the power of Colossus doubled in its processing capability. When it first went online in September 2024, it was using "100,000 Nvidia H100 processing chips". This initial launch demonstrated Colossus to be the largest supercomputer globally. The maximum power consumption increased from 150 to 250 MW. As of June 2025, the supercomputer consists of 150,000 H100 GPUs, 50,000 H200 GPUs, and 30,000 GB200 GPUs. Another 110,000 GB200 GPUs are to be brought online at a second data center, also in the Memphis area. The expansion of this supercomputer has already been discussed and will be the second phase of the project. xAI also plans to increase Colossus to 1 million GPUs. Because the supercomputer currently utilizes gas turbines for power, alongside 168 Tesla Megapack battery storage units. xAI is also looking to add more

Empowerment (artificial intelligence)

Empowerment in the field of artificial intelligence formalises and quantifies (via information theory) the potential an agent perceives that it has to influence its environment. An agent which follows an empowerment maximising policy, acts to maximise future options (typically up to some limited horizon). Empowerment can be used as a (pseudo) utility function that depends only on information gathered from the local environment to guide action, rather than seeking an externally imposed goal, thus is a form of intrinsic motivation. The empowerment formalism depends on a probabilistic model commonly used in artificial intelligence. An autonomous agent operates in the world by taking in sensory information and acting to change its state, or that of the environment, in a cycle of perceiving and acting known as the perception-action loop. Agent state and actions are modelled by random variables ( S : s ∈ S , A : a ∈ A {\displaystyle S:s\in {\mathcal {S}},A:a\in {\mathcal {A}}} ) and time ( t {\displaystyle t} ). The choice of action depends on the current state, and the future state depends on the choice of action, thus the perception-action loop unrolled in time forms a causal bayesian network. == Definition == Empowerment ( E {\displaystyle {\mathfrak {E}}} ) is defined as the channel capacity ( C {\displaystyle C} ) of the actuation channel of the agent, and is formalised as the maximal possible information flow between the actions of the agent and the effect of those actions some time later. Empowerment can be thought of as the future potential of the agent to affect its environment, as measured by its sensors. E := C ( A t ⟶ S t + 1 ) ≡ max p ( a t ) I ( A t ; S t + 1 ) {\displaystyle {\mathfrak {E}}:=C(A_{t}\longrightarrow S_{t+1})\equiv \max _{p(a_{t})}I(A_{t};S_{t+1})} In a discrete time model, Empowerment can be computed for a given number of cycles into the future, which is referred to in the literature as 'n-step' empowerment. E ( A t n ⟶ S t + n ) = max p ( a t , . . . , a t + n − 1 ) I ( A t , . . . , A t + n − 1 ; S t + n ) {\displaystyle {\mathfrak {E}}(A_{t}^{n}\longrightarrow S_{t+n})=\max _{p(a_{t},...,a_{t+n-1})}I(A_{t},...,A_{t+n-1};S_{t+n})} The unit of empowerment depends on the logarithm base. Base 2 is commonly used in which case the unit is bits. === Contextual Empowerment === In general the choice of action (action distribution) that maximises empowerment varies from state to state. Knowing the empowerment of an agent in a specific state is useful, for example to construct an empowerment maximising policy. State-specific empowerment can be found using the more general formalism for 'contextual empowerment'. C {\displaystyle C} is a random variable describing the context (e.g. state). E ( A t n ⟶ S t + n ∣ C ) = ∑ c ∈ C p ( c ) E ( A t n ⟶ S t + n ∣ C = c ) {\displaystyle {\mathfrak {E}}(A_{t}^{n}\longrightarrow S_{t+n}{\mid }C)=\sum _{c{\in }C}p(c){\mathfrak {E}}(A_{t}^{n}\longrightarrow S_{t+n}{\mid }C=c)} == Application == Empowerment maximisation can be used as a pseudo-utility function to enable agents to exhibit intelligent behaviour without requiring the definition of external goals, for example balancing a pole in a cart-pole balancing scenario where no indication of the task is provided to the agent. Empowerment has been applied in studies of collective behaviour and in continuous domains. As is the case with Bayesian methods in general, computation of empowerment becomes computationally expensive as the number of actions and time horizon extends, but approaches to improve efficiency have led to usage in real-time control. Empowerment has been used for intrinsically motivated reinforcement learning agents playing video games, and in the control of underwater vehicles.

InciWeb

InciWeb is an interagency all-risk incident web information management system provided by the United States Forest Service released in 2004. It was originally developed for wildland fire emergencies, but can be also used for other emergency incidents (natural disasters, such as earthquakes, floods, hurricanes, and tornadoes). == Introduction == It was developed with two primary missions: 1. Provide the public a single source of incident related information 2. Provide a standardized reporting tool for the Public Affairs community Official announcements include evacuations, road closures, news releases, maps, photographs, and basic info and current situation about the incident. Incident information can be accessed by: web browser at https://inciweb.wildfire.gov/ Twitter RSS web feed == Technical == The original application was hosted at the United States Forest Service - Wildland Fire Training and Conference Center, at McClellan Airfield, California, comprising three servers: Database server Administrative server Load balancer for the public content which routes traffic to a pool of eight servers. Web traffic averages 2 million plus hits daily during the fire season with the ability to handle 3.5 million hits. The servers were moved to the National information Technology Center (NITC), Kansas City, Missouri on July 16, 2008, along with the release of version 2.0; the current version is 2.2. == Availability issues == InciWeb was having technical difficulties due to the high volume of Internet users trying to access the site during the September–October 2006 Day Fire and the Summer 2008 California wildfires. == Participating agencies == United States Forest Service Bureau of Land Management Bureau of Indian Affairs Fish and Wildlife Service National Park Service National Oceanic & Atmospheric Administration Department of the Interior Office of Aircraft Services National Association of State Foresters United States Fire Administration These same agencies are also in the National Interagency Fire Center.

Content Disarm and Reconstruction

Content Disarm and Reconstruction (CDR) is a computer security technology for removing potentially malicious code from files. Unlike malware analysis, CDR technology does not determine or detect malware's functionality but removes all file components that are not approved within the system's definitions and policies. It is used to prevent cyber security threats from entering a corporate network perimeter. Channels that CDR can be used to protect include email and website traffic. Advanced solutions can also provide similar protection on computer endpoints, or cloud email and file sharing services. There are three levels of CDR; 1) flattening and converting the original file to a PDF, 2) stripping active content while keeping the original file type, and 3) eliminating all file-borne risk while maintaining file type, integrity and active content. Beyond these three levels, there are also more advanced forms of CDR that is able to perform "soft conversion" and "hard conversion", based on the user's preference in balancing usability and security. == Applications == CDR works by processing all incoming files of an enterprise network, deconstructing them, and removing the elements that do not match the file type's standards or set policies. CDR technology then rebuilds the files into clean versions that can be sent on to end users as intended. Because CDR removes all potentially malicious code, it can be effective against zero-day vulnerabilities that rely on being an unknown threat that other security technologies would need to patch against to maintain protection. CDR can be used to prevent cyber threats from variety of sources: Email Data Diodes Web Browsers Endpoints File Servers FTP Cloud email or webmail programs SMB/CIFS Removable media scanning (CDR Kiosk) CDR can be applied to a variety of file formats including: Images Office documents PDF Audio/video file formats Archives HTML == Open source implementations == DocBleach ExeFilter

Deblurring

Deblurring is the process of removing blurring artifacts from images. Deblurring recovers a sharp image S from a blurred image B, where S is convolved with K (the blur kernel) to generate B. Mathematically, this can be represented as B = S ∗ K {\displaystyle B=SK} (where represents convolution). While this process is sometimes known as unblurring, deblurring is the correct technical word. The blur K is typically modeled as point spread function and is convolved with a hypothetical sharp image S to get B, where both the S (which is to be recovered) and the point spread function K are unknown. This is an example of an inverse problem. In almost all cases, there is insufficient information in the blurred image to uniquely determine a plausible original image, making it an ill-posed problem. In addition the blurred image contains additional noise which complicates the task of determining the original image. This is generally solved by the use of a regularization term to attempt to eliminate implausible solutions. This problem is analogous to echo removal in the signal processing domain. Nevertheless, when coherent beam is used for imaging, the point spread function can be modeled mathematically. By proper deconvolution of the point spread function K and the blurred image B, the blurred image B can be deblurred (unblur) and the sharp image S can be recovered.

Environmental impact of AI

The environmental impact of the design, training, deployment and use of artificial intelligence includes the greenhouse gas emissions from generating electricity for data centres and computing hardware, operational and upstream water use, and material impacts from hardware manufacturing, mining and electronic waste. Estimating AI's environmental effects can be difficult because results depend on how impacts are measured, including whether accounting includes only model computation or also data-centre overhead, idle capacity, hardware manufacture, and local electricity supply. As these issues have received greater attention, governments and regulators have increasingly considered data-centre reporting requirements, energy-efficiency standards, and broader transparency measures for AI-related resource use. == Carbon footprint and energy use == AI-related energy use arises at multiple stages, including model training, fine-tuning, inference, storage, networking, and supporting infrastructure such as cooling and power conversion. === Individual level === Published estimates of energy use per AI request vary widely across models, tasks and measurement methods. A benchmark study presented at the 2024 ACM Conference on Fairness, Accountability, and Transparency found substantial differences between task types, with lower energy use for some text tasks and much higher energy use for image generation in the study's test conditions. In that benchmark, simple classification tasks consumed about 0.002–0.007 Wh per prompt on average (about 9% of a smartphone charge for 1,000 prompts), while text generation and text summarisation each used about 0.05 Wh per prompt; image generation averaged 2.91 Wh per prompt, and the least efficient image model in the study used 11.49 Wh per image (roughly equivalent to half a smartphone charge). First-party measurements in production environments have also been published. A 2025 Google study on Gemini assistant serving reported median per-prompt energy, emissions, and water-use estimates under the authors' accounting framework, while noting that different system boundaries can produce substantially different results. The study reported a median text-prompt estimate of about 0.24 Wh, which is roughly as much energy as watching nine seconds of television. The study also stated that software and infrastructure improvements reduced energy use by a factor of 33 and carbon emissions by a factor of 44 for a typical prompt over one year within the authors' framework. Researchers at the University of Michigan measured the energy consumption of various Meta Llama 3.1 models released in 2024 and found that smaller language models (8 billion parameters) use about 114 joules (0.03167 Wh) per response, while larger models (405 billion parameters) require up to 6,700 joules (1.861 Wh) per response. This corresponds to the energy needed to run a microwave oven for roughly one-tenth of a second and eight seconds, respectively. Comparisons between AI systems and human labour for specific tasks have produced mixed results and remain sensitive to assumptions about output quality, workload and system boundaries. A 2024 study in Scientific Reports reported 130 to 2900 times lower estimated carbon emissions for selected AI systems than for human writers and illustrators under its assumptions. A later Scientific Reports paper reported a counterexample for programming tasks under its assumptions, finding 5 to 19 times higher estimated emissions for the evaluated AI system than for human programmers on the benchmark used in that study. === System level === ==== Energy use and efficiency ==== AI electricity intensity depends not only on model architecture but also on hardware and facility efficiency. Data-centre operators commonly report Power usage effectiveness (PUE), which measures the ratio of total facility energy to IT equipment energy; a lower PUE indicates less overhead energy for cooling and other supporting infrastructure. Operators may also publish metrics and case studies on hardware efficiency, cooling systems and power sourcing. In its 2024 environmental report, Google stated that its 2023 total greenhouse gas emissions increased 13% year over year, primarily because of increased data-centre energy consumption and supply-chain emissions, while also reporting lower PUE than industry averages for its own facilities. The International Energy Agency has also reported that data centres remain a relatively small share of global electricity use overall, but that their local effects can be much more pronounced because demand is geographically concentrated. ==== Carbon footprint ==== At system level, AI contributes to rising electricity demand in data centres and related infrastructure. The International Energy Agency estimated that data centres used about 415 TWh of electricity in 2024, or around 1.5% of global electricity consumption, and projected that data-centre electricity use could rise to about 945 TWh by 2030, with AI identified as the main driver of that growth alongside other digital services. The carbon footprint of AI systems depends strongly on electricity sources, hardware efficiency, utilisation rates, and what stages are included in the accounting. Training large models can require substantial electricity, while total lifecycle impacts also depend on deployment scale and the amount of inference performed after training. Early analyses of frontier-model development reported rapid historical growth in training compute for selected systems, although later trends have depended on changes in model design, hardware and efficiency gains. Accounting methods that include upstream or embodied impacts, such as hardware manufacture and facilities construction, can materially affect estimates of AI-related emissions. === Decisions and strategies by individual companies === Large technology companies have reported that the expansion of AI and cloud infrastructure affects their sustainability targets, electricity demand, and resource use. Google, for example, attributed part of its emissions growth in 2023 to increased data-centre energy consumption and supply-chain emissions in its 2024 environmental report. Cloud and AI companies have also announced measures intended to reduce environmental impacts, including investment in more efficient hardware, low-carbon electricity procurement, alternative cooling systems, and water stewardship programmes. The extent, comparability, and third-party verification of such disclosures vary between firms and jurisdictions. == Water usage == Data centres can use water directly for cooling and indirectly through the water used in electricity generation, depending on the local energy mix. Public reporting on data-centre water use has often been inconsistent, making comparisons between operators and regions difficult. To standardise operational reporting, The Green Grid proposed the metric water usage effectiveness (WUE), defined as annual site water use divided by IT equipment energy use. WUE does not by itself measure local water stress, source sustainability, or all upstream water impacts. Studies of AI water use also distinguish between water withdrawal and water consumption. Research on AI-specific water use has argued that the water footprint of AI systems can be difficult to observe and may vary substantially by location, cooling design, and electricity source. A 2025 Communications of the ACM article summarised methods for estimating AI water footprints and emphasised the distinction between water withdrawal and water consumption. Li and colleagues estimated that global AI water withdrawal could reach 4.2–6.6 billion cubic metres in 2027 under the scenarios examined in their article. Using GPT-3, released by OpenAI in 2020, as an example, they estimated that training the model in Microsoft's U.S. data centres could consume about 700,000 litres of onsite water and about 5.4 million litres in total when offsite electricity-related water use was included; they also estimated that 10–50 medium-length GPT-3 responses could consume about 500 mL of water, depending on when and where the model was deployed. Published prompt-level estimates have also varied by system and accounting framework: the 2025 Google study on Gemini assistant serving reported a median text-prompt estimate of about 0.26 mL under its framework. Location can materially affect the significance of data-centre water use. Research on U.S. data centres found that one-fifth of servers' direct water footprint came from moderately to highly water-stressed watersheds, while nearly half of servers were fully or partially powered by plants located in water-stressed regions. A 2025 Reuters report, citing data from Verisk Maplecroft and NatureFinance, said that an average mid-sized data centre uses about 1.4 million litres of water per day for cooling and that Phoenix would experience a 32% increase in annual water stress if currently pl

Flat-field correction

Flat-field correction (FFC) is a digital imaging technique to mitigate pixel-to-pixel differences in the photodetector sensitivity and distortions in the optical path. It is a standard calibration procedure in everything from personal digital cameras to large telescopes. == Overview == Flat fielding refers to the process of compensating for different gains and dark currents in a detector. Once a detector has been appropriately flat-fielded, a uniform signal will create a uniform output (hence flat-field). This then means any further signal is due to the phenomenon being detected and not a systematic error. A flat-field image is acquired by imaging a uniformly-illuminated screen, thus producing an image of uniform color and brightness across the frame. For handheld cameras, the screen could be a piece of paper at arm's length, but a telescope will frequently image a clear patch of sky at twilight, when the illumination is uniform and there are few, if any, stars visible. Once the images are acquired, processing can begin. A flat-field consists of two numbers for each pixel, the pixel's gain and its dark current (or dark frame). The pixel's gain is how the amount of signal given by the detector varies as a function of the amount of light (or equivalent). The gain is almost always a linear variable, as such the gain is given simply as the ratio of the input and output signals. The dark-current is the amount of signal given out by the detector when there is no incident light (hence dark frame). In many detectors this can also be a function of time, for example in astronomical telescopes it is common to take a dark-frame of the same time as the planned light exposure. The gain and dark-frame for optical systems can also be established by using a series of neutral density filters to give input/output signal information and applying a least squares fit to obtain the values for the dark current and gain. C = ( R − D ) × m ( F − D ) = ( R − D ) × G {\displaystyle C={\frac {(R-D)\times m}{(F-D)}}=(R-D)\times G} where: C = corrected image R = raw image F = flat field image D = dark frame image m = image-averaged value of (F−D) G = Gain = m ( F − D ) {\displaystyle m \over (F-D)} In this equation, capital letters are 2D matrices, and lowercase letters are scalars. All matrix operations are performed element-by-element. In order for an astrophotographer to capture a light frame, they must place a light source over the imaging instrument's objective lens such that the light source emanates evenly through the users optics. The photographer must then adjust the exposure of their imaging device (charge-coupled device (CCD) or digital single-lens reflex camera (DSLR) ) so that when the histogram of the image is viewed, a peak reaching about 40–70% of the dynamic range (maximum range of pixel values) of the imaging device is seen. The photographer typically takes 15–20 light frames and performs median stacking. Once the desired light frames are acquired, the objective lens is covered so that no light is allowed in, then 15–20 dark frames are taken, each of equal exposure time as a light frame. These are called Dark-Flat frames. == In X-ray imaging == In X-ray imaging, the acquired projection images generally suffer from fixed-pattern noise, which is one of the limiting factors of image quality. It may stem from beam inhomogeneity, gain variations of the detector response due to inhomogeneities in the photon conversion yield, losses in charge transport, charge trapping, or variations in the performance of the readout. Also, the scintillator screen may accumulate dust and/or scratches on its surface, resulting in systematic patterns in every acquired X-ray projection image. In X-ray computed tomography (CT), fixed-pattern noise is known to significantly degrade the achievable spatial resolution and generally leads to ring or band artifacts in the reconstructed images. Fixed pattern noise can be easily removed using flat field correction. In conventional flat field correction, projection images without sample are acquired with and without the X-ray beam turned on, which are referred to as flat fields (F) and dark fields (D). Based on the acquired flat and dark fields, the measured projection images (P) with sample are then normalized to new images (N) according to: N = ( P − D ) ( F − D ) {\displaystyle N={\frac {(P-D)}{(F-D)}}} == Dynamic flat field correction == While conventional flat field correction is an elegant and easy procedure that largely reduces fixed-pattern noise, it heavily relies on the stationarity of the X-ray beam, scintillator response and CCD sensitivity. In practice, however, this assumption is only approximately met. Indeed, detector elements are characterized by intensity dependent, nonlinear response functions and the incident beam often shows time dependent non-uniformities, which render conventional FFC inadequate. In synchrotron X-ray tomography, many factors may cause flat field variations: instability of the bending magnets of the synchrotron, temperature variations due to the water cooling in mirrors and the monochromator, or vibrations of the scintillator and other beamline components. The latter is responsible for the biggest variations in the flat fields. To deal with such variations, a dynamic flat field correction procedure can be employed that estimates a flat field for each individual projection. Through principal component analysis of a set of flat fields, which are acquired prior and/or posterior to the actual scan, eigen flat fields can be computed. A linear combination of the most important eigen flat fields can then be used to individually normalize each X-ray projection: N j = P j − D ¯ F ¯ + ∑ k w j k u k − D ¯ {\displaystyle N_{j}={\frac {P_{j}-{\bar {D}}}{{\bar {F}}+\sum _{k}w_{jk}u_{k}-{\bar {D}}}}} where N j {\displaystyle N_{j}} = intensity normalized X-ray projection P j {\displaystyle P_{j}} = raw X-ray projection F ¯ {\displaystyle {\bar {F}}} = mean flat field image (average of flat fields) u k {\displaystyle u_{k}} = k-th eigen flat field w j k {\displaystyle w_{jk}} = weight of the eigen flat field u k {\displaystyle u_{k}} D ¯ {\displaystyle {\bar {D}}} = mean dark field (average of dark fields)