Deep Learning Studio is a software tool that aims to simplify the creation of deep learning models used in artificial intelligence. It is compatible with a number of open-source programming frameworks popularly used in artificial neural networks, including MXNet and Google's TensorFlow. Prior to the release of Deep Learning Studio in January 2017, proficiency in Python, among other programming languages, was essential in developing effective deep learning models. Deep Learning Studio sought to simplify the model creation process through a visual, drag-and-drop interface and the application of pre-trained learning models on available data. Irving, Texas–based Deep Cognition Inc. is the developer behind Deep Learning Studio. In 2017, the software allowed Deep Cognition to become a finalist for Best Innovation in Deep Learning in the Alconics Awards, which are given annually to the best artificial intelligence software. Deep Cognition launched version 2.0 of Deep Learning Studio at NVIDIA's GTC 2018 Conference in San Jose, California. Fremont, California–based computing products supplier Exxact Corp provides desktop computers specifically built to handle Deep Learning Studio workloads. == Features == Source: Deep Learning Studio is available in two versions: Desktop and Cloud, both of which are free software. The Desktop version is available on Windows and Ubuntu. The Cloud version is available in single-user and multi-user configurations. A Deep Cognition account is needed to access the Cloud version. Account registration is free. Deep Learning Studio can import existing Keras models; it also takes a data set as an input. Deep Learning Studio's AutoML feature allows automatic generation of deep learning models. More advanced users may choose to generate their own models using various types of layers and neural networks. Deep Learning Studio also has a library of loss functions and optimizers for use in hyperparameter tuning, a traditionally complicated area in neural network programming. Generated models can be trained using either CPUs or GPUs. Trained models can then be used for predictive analytics.
Time-inhomogeneous hidden Bernoulli model
Time-inhomogeneous hidden Bernoulli model (TI-HBM) is an alternative to hidden Markov model (HMM) for automatic speech recognition. Contrary to HMM, the state transition process in TI-HBM is not a Markov-dependent process, rather it is a generalized Bernoulli (an independent) process. This difference leads to elimination of dynamic programming at state-level in TI-HBM decoding process. Thus, the computational complexity of TI-HBM for probability evaluation and state estimation is O ( N L ) {\displaystyle O(NL)} (instead of O ( N 2 L ) {\displaystyle O(N^{2}L)} in the HMM case, where N {\displaystyle N} and L {\displaystyle L} are number of states and observation sequence length respectively). The TI-HBM is able to model acoustic-unit duration (e.g. phone/word duration) by using a built-in parameter named survival probability. The TI-HBM is simpler and faster than HMM in a phoneme recognition task, but its performance is comparable to HMM. For details, see [1] or [2].
Sanad (government app)
Sanad (Arabic: سند) is the official digital identity and e-government services application of the Hashemite Kingdom of Jordan. Developed and managed by the Ministry of Digital Economy and Entrepreneurship, the app provides a unified platform for accessing a range of public services and personal records digitally. == Overview == Launched in February 2020, Sanad is part of Jordan's broader digital transformation strategy aimed at improving public service delivery and enhancing administrative efficiency. The app allows users to authenticate their identity digitally and access over 550 services from more than 50 government and private sector entities. == Features == Sanad provides a wide array of services, including: Viewing and managing official digital documents Applying for government services (e.g., jordanian passport issuance or renewal, health insurance) Accessing personal records (e.g., pension, property ownership) Digitally signing documents Paying utility bills and traffic fines Receiving and tracking official notifications The app is available on iOS, Android, and HarmonyOS platforms and supports both Arabic and English languages. == Digital Identity == A core feature of Sanad is the digital identity system, which enables secure login and authentication for all integrated services. Users must activate their digital identity at designated Sanad stations across Jordan to access the full suite of services. == Adoption and Impact == As of 2025, more than 1.6 million Jordanians have activated their digital identities through Sanad. The app has played a significant role in streamlining government interactions and reducing the need for in-person visits, especially during the COVID-19 pandemic. == Recent Developments == In 2025, the Ministry launched an updated version of the app with enhanced user experience and new services, including the e-passport issuance feature.
Clipmap
In computer graphics, clipmapping is a method of clipping a mipmap to a subset of data pertinent to the geometry being displayed. This is useful for loading as little data as possible when memory is limited, such as on a graphics processing unit. The technique is used for LODing in NVIDIA’s implementation of voxel cone tracing. The high-resolution levels of the mipmapped scene representation are clipped to a region near the camera, while lower resolution levels are clipped further away. == MegaTexture == MegaTexture is a clipmap implementation developed by id Software. It was introduced in their id Tech 4 engine and also appeared in id Tech 5 and id Tech 6 before being removed in id Tech 7. MegaTexture is a texture allocation technique that uses a single, extremely large texture rather than repeating multiple smaller textures. It is also featured in Splash Damage's game Enemy Territory: Quake Wars, and was developed by id Software former technical director John Carmack. MegaTexture employs a single large texture space for static terrain. The texture is stored on removable media or a computer's hard drive and streamed as needed, allowing large amounts of detail and variation over a large area with comparatively little RAM usage. Depending on the pixel resolution per square meter, covering a large area could require several gigabytes of memory. However, RAM is also filled by the rest of the game and the underlying operating system, limiting the amount available for texturing. As the player moves around the game, different sections of the MegaTexture are loaded into memory. They are then scaled to the correct size and applied to the 3D models of the terrain. Id has presented a more advanced technique that builds upon the MegaTexture idea and virtualizes both the geometry and the textures to obtain unique geometry down to the equivalent of the texel: the sparse voxel octree (SVO). It works by raycasting the geometry represented by voxels (instead of triangles) stored in an octree. The goal is to stream parts of the octree into video memory, going further down along the tree for nearby objects to give them more details, and to use higher level, larger voxels for farther objects, which give an automatic level of detail (LOD) system for both geometry and textures at the same time. The geometric detail that can be obtained using this method is nearly infinite, which removes the need for faking 3-dimensional details with techniques such as normal mapping. Despite that most voxel rendering tests use very large amounts of memory (up to several GB), Jon Olick of id Software claimed the technology is able to compress such SVO to 1.15 bits per voxel of position data. == Virtual texturing == Unlike clipmaps, which clip each mip level around a viewpoint-dependent clipcenter and therefore work best for terrain, virtual texturing preprocesses texture data into equally sized tiles that can be streamed for arbitrary textured geometry. Rage, powered by the id Tech 5 engine, uses a more advanced technique called virtual texturing. Textures can measure up to 128000×128000 pixels and are also used for in-game models and sprites, etc. and not just the terrain. Wolfenstein: The New Order and the 2016 version of Doom also use these. Carmageddon: Reincarnation also uses virtual texturing, though unlike id's virtual texturing system, which is designed for unique texture-mapping everywhere, their system is designed to use storage space sparingly while still offering good blend of texture variation and resolution.
Jordan Antiquities Database and Information System
The Jordan Antiquities Database and Information System (JADIS) was a computer database of antiquities in Jordan, the first of its kind in the Arab world. It was established by the Department of Antiquities in 1990, in cooperation with the American Center for Oriental Research in Amman and sponsored by the United States Agency for International Development. JADIS was in use until 2002, when it was superseded by a new system, MEGA-J. Over 10,841 antiquities were registered in the database. An introduction and printed summary of the database was published by the Department of Antiquities in 1994, edited by Gaetano Palumbo.
Medical imaging
Medical imaging is the technique and process of imaging the interior of a body for clinical analysis and medical intervention, as well as visual representation of the function of some organs or tissues (physiology). Medical imaging seeks to reveal internal structures hidden by the skin and bones, as well as to diagnose and treat disease. Medical imaging also establishes a database of normal anatomy and physiology to make it possible to identify abnormalities. Although imaging of removed organs and tissues can be performed for medical reasons, such procedures are usually considered part of pathology instead of medical imaging. Measurement and recording techniques that are not primarily designed to produce images, such as electroencephalography (EEG), magnetoencephalography (MEG), electrocardiography (ECG), and others, represent other technologies that produce data susceptible to representation as a parameter graph versus time or maps that contain data about the measurement locations. In a limited comparison, these technologies can be considered forms of medical imaging in another discipline of medical instrumentation. As of 2010, 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 made up about 50% of total ionizing radiation exposure in the United States. Medical imaging equipment is manufactured using technology from the semiconductor industry, including CMOS integrated circuit chips, power semiconductor devices, sensors such as image sensors (particularly CMOS sensors) and biosensors, and processors such as microcontrollers, microprocessors, digital signal processors, media processors and system-on-chip devices. As of 2015, annual shipments of medical imaging chips amount to 46 million units and $1.1 billion. The term "noninvasive" is used to denote a procedure where no instrument is introduced into a patient's body, which is the case for most imaging techniques used. == History == In 1972, engineer Godfrey Hounsfield from the British company EMI invented the X-ray computed tomography device for head diagnosis, which is commonly referred to as computed tomography (CT). The CT nucleus method is based on the projecting X-rays through a section of the human head, which are then processed by computer to reconstruct the cross-sectional image, known as image reconstruction. In 1975, EMI successfully developed a CT device for the entire body, enabling the clear acquisition of tomographic images of various parts of the human body. This revolutionary diagnostic technique earned Hounsfield and physicist Allan Cormack the Nobel Prize in Physiology or Medicine in 1979. Digital image processing technology for medical applications was inducted into the Space Foundation's Space Technology Hall of Fame in 1994. By 2010, over 5 billion medical imaging studies had been conducted worldwide. Radiation exposure from medical imaging in 2006 accounted for about 50% of total ionizing radiation exposure in the United States. Medical imaging equipment is manufactured using technology from the semiconductor industry, including CMOS integrated circuit chips, power semiconductor devices, sensors such as image sensors (particularly CMOS sensors) and biosensors, as well as processors like microcontrollers, microprocessors, digital signal processors, media processors and system-on-chip devices. As of 2015, annual shipments of medical imaging chips reached 46 million units, generating a market value of $1.1 billion. == Types == In the clinical context, "invisible light" medical imaging is generally equated to radiology or "clinical imaging". "Visible light" medical imaging involves digital video or still pictures that can be seen without special equipment. Dermatology and wound care are two modalities that use visible light imagery. Interpretation of medical images is generally undertaken by a physician specialising in radiology known as a radiologist; however, this may be undertaken by any healthcare professional who is trained and certified in radiological clinical evaluation. Increasingly interpretation is being undertaken by non-physicians, for example radiographers frequently train in interpretation as part of expanded practice. Diagnostic radiography designates the technical aspects of medical imaging and in particular the acquisition of medical images. The radiographer (also known as a radiologic technologist) is usually responsible for acquiring medical images of diagnostic quality; although other professionals may train in this area, notably some radiological interventions performed by radiologists are done so without a radiographer. As a field of scientific investigation, medical imaging constitutes a sub-discipline of biomedical engineering, medical physics or medicine depending on the context: Research and development in the area of instrumentation, image acquisition (e.g., radiography), modeling and quantification are usually the preserve of biomedical engineering, medical physics, and computer science; Research into the application and interpretation of medical images is usually the preserve of radiology and the medical sub-discipline relevant to medical condition or area of medical science (neuroscience, cardiology, psychiatry, psychology, etc.) under investigation. Many of the techniques developed for medical imaging also have scientific and industrial applications. === Radiography === Two forms of radiographic images are in use in medical imaging. Projection radiography and fluoroscopy, with the latter being useful for catheter guidance. These 2D techniques are still in wide use despite the advance of 3D tomography due to the low cost, high resolution, and depending on the application, lower radiation dosages with 2D technique. This imaging modality uses a wide beam of X-rays for image acquisition and is the first imaging technique available in modern medicine. Fluoroscopy produces real-time images of internal structures of the body in a similar fashion to radiography, but employs a constant input of X-rays, at a lower dose rate. Contrast media, such as barium, iodine, and air are used to visualize internal organs as they work. Fluoroscopy is also used in image-guided procedures when constant feedback during a procedure is required. An image receptor is required to convert the radiation into an image after it has passed through the area of interest. Early on, this was a fluorescing screen, which gave way to an Image Amplifier (IA) which was a large vacuum tube that had the receiving end coated with cesium iodide, and a mirror at the opposite end. Eventually the mirror was replaced with a TV camera. Projectional radiographs, more commonly known as X-rays, are often used to determine the type and extent of a fracture as well as for detecting pathological changes in the lungs. With the use of radio-opaque contrast media, such as barium, they can also be used to visualize the structure of the stomach and intestines – this can help diagnose ulcers or certain types of colon cancer. === Magnetic resonance imaging === A magnetic resonance imaging instrument (MRI scanner), or "nuclear magnetic resonance (NMR) imaging" scanner as it was originally known, uses powerful magnets to polarize and excite hydrogen nuclei (i.e., single protons) of water molecules in human tissue, producing a detectable signal that is spatially encoded, resulting in images of the body. The MRI machine emits a radio frequency (RF) pulse at the resonant frequency of the hydrogen atoms on water molecules. Radio frequency antennas ("RF coils") send the pulse to the area of the body to be examined. The RF pulse is absorbed by protons, causing their direction with respect to the primary magnetic field to change. When the RF pulse is turned off, the protons "relax" back to alignment with the primary magnet and emit radio waves in the process. This radio-frequency emission from the hydrogen atoms on water is what is detected and reconstructed into an image. The resonant frequency of a spinning magnetic dipole (of which protons are one example) is called the Larmor frequency and is determined by the strength of the main magnetic field and the chemical environment of the nuclei of interest. MRI uses three electromagnetic fields: a very strong (typically 1.5 to 3 teslas) static magnetic field to polarize the hydrogen nuclei, called the primary field; gradient fields that can be modified to vary in space and time (on the order of 1 kHz) for spatial encoding, often simply called gradients; and a spatially homogeneous radio-frequency (RF) field for manipulation of the hydrogen nuclei to produce measurable signals, collected through an RF antenna. Like CT, MRI traditionally creates a two-dimensional image of a thin "slice" of the body and is therefore considered a tomographic imaging technique. Modern MRI instruments are capable of producing images in the form of 3D blocks, which may be considered a generalization of the single-slice
Hit-testing
In computer graphics programming, hit-testing (hit detection, picking, or pick correlation) is the process of determining whether a user-controlled cursor (such as a mouse cursor or touch-point on a touch-screen interface) intersects a given graphical object (such as a shape, line, or curve) drawn on the screen. Hit-testing may be performed on the movement or activation of a mouse or other pointing device. Hit-testing is used by GUI environments to respond to user actions, such as selecting a menu item or a target in a game based on its visual location. In web programming languages such as HTML, SVG, and CSS, this is associated with the concept of pointer-events (e.g. user-initiated cursor movement or object selection). Collision detection is a related concept for detecting intersections of two or more different graphical objects, rather than intersection of a cursor with one or more graphical objects. == Algorithm == There are many different algorithms that may be used to perform hit-testing, with different performance or accuracy outcomes. One common hit-test algorithm for axis aligned bounding boxes. A key idea is that the box being tested must be either entirely above, entirely below, entirely to the right or left of the current box. If this is not possible, they are colliding. Example logic is presented in the pseudo-code below: In Python: