Transfer function matrix
In control system theory, and various branches of engineering, a transfer function matrix, or just transfer matrix is a generalisation of the transfer functions of single-input single-output (SISO) systems to multiple-input and multiple-output (MIMO) systems. The matrix relates the outputs of the system to its inputs. It is a particularly useful construction for linear time-invariant (LTI) systems because it can be expressed in terms of the s-plane. In some systems, especially ones consisting entirely of passive components, it can be ambiguous which variables are inputs and which are outputs. In electrical engineering, a common scheme is to gather all the voltage variables on one side and all the current variables on the other regardless of which are inputs or outputs. This results in all the elements of the transfer matrix being in units of impedance. The concept of impedance (and hence impedance matrices) has been borrowed into other energy domains by analogy, especially mechanics and acoustics. Many control systems span several different energy domains. This requires transfer matrices with elements in mixed units. This is needed both to describe transducers that make connections between domains and to describe the system as a whole. If the matrix is to properly model energy flows in the system, compatible variables must be chosen to allow this. == General == A MIMO system with m outputs and n inputs is represented by a m × n matrix. Each entry in the matrix is in the form of a transfer function relating an output to an input. For example, for a three-input, two-output system, one might write, [ y 1 y 2 ] = [ g 11 g 12 g 13 g 21 g 22 g 23 ] [ u 1 u 2 u 3 ] {\displaystyle {\begin{bmatrix}y_{1}\\y_{2}\end{bmatrix}}={\begin{bmatrix}g_{11}&g_{12}&g_{13}\\g_{21}&g_{22}&g_{23}\end{bmatrix}}{\begin{bmatrix}u_{1}\\u_{2}\\u_{3}\end{bmatrix}}} where the un are the inputs, the ym are the outputs, and the gmn are the transfer functions. This may be written more succinctly in matrix operator notation as, Y = G U {\displaystyle \mathbf {Y} =\mathbf {G} \mathbf {U} } where Y is a column vector of the outputs, G is a matrix of the transfer functions, and U is a column vector of the inputs. In many cases, the system under consideration is a linear time-invariant (LTI) system. In such cases, it is convenient to express the transfer matrix in terms of the Laplace transform (in the case of continuous time variables) or the z-transform (in the case of discrete time variables) of the variables. This may be indicated by writing, for instance, Y ( s ) = G ( s ) U ( s ) {\displaystyle \mathbf {Y} (s)=\mathbf {G} (s)\mathbf {U} (s)} which indicates that the variables and matrix are in terms of s, the complex frequency variable of the s-plane arising from Laplace transforms, rather than time. The examples in this article are all assumed to be in this form, although that is not explicitly indicated for brevity. For discrete time systems s is replaced by z from the z-transform, but this makes no difference to subsequent analysis. The matrix is particularly useful when it is a proper rational matrix, that is, all its elements are proper rational functions. In this case, the state-space representation can be applied. In systems engineering, the overall system transfer matrix G (s) is decomposed into two parts: H (s) representing the system being controlled, and C(s) representing the control system. C (s) takes as its inputs the inputs of G (s) and the outputs of H (s). The outputs of C (s) form the inputs for H (s). == Electrical systems == In electrical systems, it is often the case that the distinction between input and output variables is ambiguous. They can be either, depending on circumstance and point of view. In such cases, the concept of port (a place where energy is transferred from one system to another) can be more useful than input and output. It is customary to define two variables for each port (p): the voltage across it (Vp) and the current entering it (Ip). For instance, the transfer matrix of a two-port network can be defined as follows, [ V 1 V 2 ] = [ z 11 z 12 z 21 z 22 ] [ I 1 I 2 ] {\displaystyle {\begin{bmatrix}V_{1}\\V_{2}\end{bmatrix}}={\begin{bmatrix}z_{11}&z_{12}\\z_{21}&z_{22}\\\end{bmatrix}}{\begin{bmatrix}I_{1}\\I_{2}\end{bmatrix}}} where the zmn are called the impedance parameters, or z-parameters. They are so-called because they are in units of impedance and relate port currents to a port voltage. The z-parameters are not the only way that transfer matrices are defined for two-port networks. Six basic matrices relate voltages and currents, each with advantages for particular system network topologies. However, only two of these can be extended beyond two ports to an arbitrary number of ports. These two are the z-parameters and their inverse, the admittance parameters or y-parameters. To understand the relationship between port voltages and currents and inputs and outputs, consider the simple voltage divider circuit. If we only wish to consider the output voltage (V2) resulting from applying the input voltage (V1) then the transfer function can be expressed as, [ V 2 ] = [ R 2 R 1 + R 2 ] [ V 1 ] {\displaystyle {\begin{bmatrix}V_{2}\end{bmatrix}}={\begin{bmatrix}{\dfrac {R_{2}}{R_{1}+R_{2}}}\end{bmatrix}}{\begin{bmatrix}V_{1}\end{bmatrix}}} which can be considered the trivial case of a 1×1 transfer matrix. The expression correctly predicts the output voltage if there is no current leaving port 2, but is increasingly inaccurate as the load increases. If, however, we attempt to use the circuit in reverse, driving it with a voltage at port 2 and calculate the resulting voltage at port 1 the expression gives completely the wrong result even with no load on port 1. It predicts a greater voltage at port 1 than was applied at port 2, an impossibility with a purely resistive circuit like this one. To correctly predict the behaviour of the circuit, the currents entering or leaving the ports must also be taken into account, which is what the transfer matrix does. The impedance matrix for the voltage divider circuit is, [ V 1 V 2 ] = [ R 1 + R 2 R 2 R 2 R 2 ] [ I 1 I 2 ] {\displaystyle {\begin{bmatrix}V_{1}\\V_{2}\end{bmatrix}}={\begin{bmatrix}R_{1}+R_{2}&R_{2}\\R_{2}&R_{2}\end{bmatrix}}{\begin{bmatrix}I_{1}\\I_{2}\end{bmatrix}}} which fully describes its behaviour under all input and output conditions. At microwave frequencies, none of the transfer matrices based on port voltages and currents are convenient to use in practice. Voltage is difficult to measure directly, current next to impossible, and the open circuits and short circuits required by the measurement technique cannot be achieved with any accuracy. For waveguide implementations, circuit voltage and current are entirely meaningless. Transfer matrices using different sorts of variables are used instead. These are the powers transmitted into, and reflected from a port, which are readily measured in the transmission line technology used in distributed-element circuits in the microwave band. The most well-known and widely used of these sorts of parameters is the scattering parameters, or s-parameters. == Mechanical and other systems == The concept of impedance can be extended into the mechanical and other domains through a mechanical-electrical analogy, hence the impedance parameters and other forms of 2-port network parameters can also be extended to the mechanical domain. To do this, an effort variable and a flow variable are made analogues of voltage and current, respectively. For mechanical systems under translation these variables are force and velocity respectively. Expressing the behaviour of a mechanical component as a two-port or multi-port with a transfer matrix is a useful thing to do because, like electrical circuits, the component can often be operated in reverse and its behaviour is dependent on the loads at the inputs and outputs. For instance, a gear train is often characterised simply by its gear ratio, a SISO transfer function. However, the gearbox output shaft can be driven around to turn the input shaft, requiring a MIMO analysis. In this example, the effort and flow variables are torque T and angular velocity ω, respectively. The transfer matrix in terms of z-parameters will look like, [ T 1 T 2 ] = [ z 11 z 12 z 21 z 22 ] [ ω 1 ω 2 ] {\displaystyle {\begin{bmatrix}T_{1}\\T_{2}\end{bmatrix}}={\begin{bmatrix}z_{11}&z_{12}\\z_{21}&z_{22}\end{bmatrix}}{\begin{bmatrix}\omega _{1}\\\omega _{2}\end{bmatrix}}} However, the z-parameters are not necessarily the most convenient for characterising gear trains. A gear train is the analogue of an electrical transformer and the h-parameters (hybrid parameters) better describe transformers because they directly include the turns ratios (the analogue of gear ratios). The gearbox transfer matrix in h-parameter format is, [ T 1 ω 2 ] = [ h 11 h 12 h 21 h 22 ] [ ω 1 T 2 ] {\displaystyle {\begin{bmatrix}T_{1}\\\omega _{2}\end{bm
Read more →



